Jotul GF300 DV Stove User Manual


 
4
Specifications
GF 300 DV Specifications
Input Rates
Natural Gas
26,000 BTU/hr. maximum input
14,000 BTU/hr. minimum input
Propane
26,000 BTU/hr. maximum input
14,000 BTU/hr. minimum input
Inlet Pressure: MIN MAX
Natural Gas: 5.0 WC (1.24 kPa) 7.0 WC (1.74 kPa)
Propane: 12.0 WC (2.99 kPa) 14.9 WC (3.71 kPa)
Manifold Pressure: MIN MAX
Natural Gas: 1.2 WC (.30 kPa) 3.8 WC (.95 kPa)
Propane: 2.9 WC (.722 kPa) 11.0 WC (2.74 kPa)
Piezo Ignitor / Standing Pilot
C
L
25 ”
635 mm
28 ”
711 mm
3 1/4”
83 mm
28 1/2”
724 mm
13”
330 mm
15 1/4”
500 mm
27 1/2”
698 mm
22 1/4”
565 mm
22 1/2”
572 mm
C
L
Suggested Tools for
Installation and Service
External regulator (for Propane only)
Piping which complies with local code
Manual shutoff valve (T-Handle in Massachusetts)
Sediment trap - if required by code
Tee joint
Pipe wrench
Pipe sealant
10 mm open end wrench
1/2”, 7/16” open end wrench or deep socket
Phillips head screwdriver
Flat head screwdriver
1/4” nut driver
4 mm allen wrench
Gloves
Safety glasses
Torx T20 screwdriver
Leak test solution
Reciprocating Saw
Power Drill