Jotul GF300 DV Stove User Manual


 
10
HORIZONTAL RUN
35 Ft.
(10.67 m)
30 Ft.
(9.14 m)
25 Ft.
(7.62 m)
20 Ft.
(6.10 m)
15 Ft.
(4.57 m)
5 Ft.
(1.52 m)
10 Ft.
(3.05 m)
5 Ft.
(1.52 m)
VERTICAL RUN
15 Ft.
(4.57 m)
20 Ft.
(6.09 m)
27 Ft.
(8.22m)
12 Ft.
(3.65 m)
8 Ft.
(2.43 m)
A
D
Min. Rise
2 Ft.
(.60 m)
Up to four 45° or
two 90° elbows
permitted in
addition to the
starter elbow.
B
B
A
C
Min. Vertical
Termination
Figure 9. Coaxial Vent Termination Window / NG
Figure 10 . Colinear Termination / NG
ALL VENTING MUST TERMINATE (END) WITHIN ONE OF
THE SHADED AREAS.
SET STOVE EXHAUST RESTRICTOR TO THE POSITION THAT
CORRESPONDS TO THE VENT TERMINATION AREA IN THE
DIAGRAM ABOVE.
ALWAYS MAINTAIN THE PROPER CLEARANCES TO
COMBUSTIBLES.
The circled letter designations in the vent diagram correspond
to the Exhaust Restrictor Setting on the stove. First, determine
which vent termination zone is appropriate for your installation
and fuel type, then adjust the restrictor to the corresponding
position as shown in figure 7, page 9.
Vent Windows for Natural Gas
COLINEAR VENT
COAXIAL VENT
VENTING MUST TERMI-
NATE (END) WITHIN THE
SHADED AREA.
Adjust the Exhaust
Restrictor to position B
for any NG colinear
termination.
Max. Offset: 2 ft. (610
mm)
HORIZONTAL RUN
35 Ft.
(10.67 m)
25 Ft.
(7.62 m)
2 Ft.
(16 cm)
VERTICAL RUN
Minimum
Vertical
Termination
8 Ft.
(2.43 m)
35 Ft.
(10.67 m)
25 Ft.
(7.62 m)
2 Ft.
(16 cm)
VERTICAL RUN
Minimum
Vertical
Termination
8 Ft.
(2.43 m)
45°
Elbow
Up
B