Figure 22. Locate and remove the Air Shutter wingnut
from under the right side of the stove.
Tools required:
1/2” open ended wrench or deep-well socket, Torx T20
or slotted screwdriver, 4 mm allen wrench.
Conversion Kit Contents:
1, regulator tower labeled for propane
3, regulator tower screws
1, burner orifice (#39 for NG, #53 for LPG)
1, pilot orifice (#51 for NG, #30 for LPG)
Label A - to be completed and applied to
the back of the stove
Label B - apply to the stove’s Rating Plate
Small valve label - apply to valve body
Conversion instructions are also shipped in the stove
with the conversion kit.
Mobile Home Installation
The GF 300 DV can be installed for use in a mobile home
in the U.S. and Canada provided:
1. The stove is secured to the floor of the mobile home.
Use Jøtul Floor Bracket Kit #154388.
2. Provision must be made to secure an electrical ground
between the stove and the mobile home chassis.
3. The stove is installed in accordance with Title 24 CFR,
Part 3280- Manufactured Home Construction and
Safety Standard, in the U.S. In Canada, comply with
CSA Z240.4, Gas Equipped Recreational Vehicles and
Mobile Housing.
4. Always contact your local officials about installation
restrictions and requirements in your area.
THIS APPLIANCE MAY BE INSTALLED AS AN
OEM INSTALLATION IN A MANUFACTURED
(MOBILE) HOME AND MUST BE INSTALLED IN
ACCORDANCE WITH THE MANUFACTURER’S
INSTRUCTIONS AND THE MANUFACTURED
HOME CONSTRUCTION AND SAFETY STAN-
DARD, TITLE 24 CFR, PART 3280. THIS APPLI-
ANCE IS ONLY FOR USE WITH THE TYPE OF
GAS THAT IS INDICATED ON THE STOVE’S
RATING PLATE. A GAS CONVERSION KIT IS
PROVIDED WITH THE GF 300 DV GAS STOVE.
THIS APPLIANCE MAY BE INSTALLED IN AN
AFTERMARKET PERMANENTLY LOCATED,
MANUFACTURED (MOBILE) HOME, WHERE
NOT PROHIBITED BY LOCAL CODES.
CET APPAREIL PEUT ETRE INSTALLE DANS
UN MAISON PREFABRIQUEE (MOBILE) DEJA
INSTALLEE A DEMEURE SI LES REGLEMENTS
LOCAUX LE PERMETTENT. CET APPAREIL
DOIT ETRE UTILISE UNIQUEMENT AVEC LES
TYPES DE GAS INDIQUES SUR LA PLAQUE
SIGNALETIQUE. NE PAS L’UTILISER AVEC
D’AUTRES GAS SAUF SI UN KITDE CONVER-
SION CERTIFIE EST INSTALLE.
Fuel Conversion
The GF 300 DV gas stove is shipped from the factory
equipped to burn NATURAL GAS only. If PROPANE gas is
to be used as fuel, the appliance must first be converted
for use with propane. Use Propane Conversion Kit
155372, supplied with the appliance.
Order and install NG Conversion Kit 155373 to
change back to use with natural gas.
WARNING:
THE CONVERSION KIT IS TO BE
INSTALLED BY AN AUTHORIZED JØTUL
SERVICE TECHNICIAN IN ACCORDANCE
WITH THE MANUFACTURER’S
INSTRUCTION AND ALL CODES AND
REQUIREMENTS OF THE AUTHORITY
HAVING JURISDICTION. FAILURE TO
FOLLOW THESE INSTRUCTIONS COULD
RESULT IN SERIOUS INJURY OR
PROPERTY DAMAGE. THE QUALIFIED
AGENCY PERFORMING THIS WORK
ASSUMES RESPONSIBILITY FOR THIS
CONVERSION.
IN CANADA:
THE CONVERSION SHALL BE CARRIED
OUT IN ACCORDANCE WITH THE RE-
QUIREMENTS OF THE PROVINCIAL AU-
THORITIES HAVING JURISDICTION AND
IN ACCORDANCE WITH THE REQUIRE-
MENTS OF THE CAN1-B149.1 AND .2