Jotul GF300 DV Stove User Manual


 
11
HORIZONTAL RUN
35 Ft.
(10.67 m)
30 Ft.
(9.14 m)
25 Ft.
(7.62 m)
20 Ft.
(6.10 m)
15 Ft.
(4.57 m)
5 Ft.
(1.52 m)
Min. Rise
2 Ft.
(.60 m)
10 Ft.
(3.05 m)
5 Ft.
(1.52 m)
VERTICAL RUN
15 Ft.
(4.57 m)
20 Ft.
(6.09 m)
27 Ft.
(8.22m)
12 Ft.
(3.65 m)
8 Ft.
(2.43 m)
A
D
C
C
Min. Vertical
Termination
Up to four 45° or
two 90° elbows
permitted in
addition to the
starter elbow.
Figure 11. Coaxial Vent Termination Window / LP Figure 12 . Colinear Termination / LP
Vent Windows for Propane
COAXIAL VENT
COLINEAR VENT
VENTING MUST
TERMINATE (END) WITHIN
THE SHADED AREA.
Adjust the Exhaust
Restrictor to position C for
a vertical colinear
termination.
Max. Offset: 2 ft. (610 mm)
VENTING MUST TERMINATE (END) WITHIN ONE OF THE
DESIGNATED AREAS.
SET STOVE EXHAUST RESTRICTOR TO THE POSITION THAT
CORRESPONDS TO THE VENT TERMINATION AREA IN THE
DIAGRAM ABOVE.
ALWAYS MAINTAIN THE PROPER CLEARANCES TO
COMBUSTIBLES.
The circled letter designations in the vent diagram correspond
to the Exhaust Restrictor Setting on the stove. First, determine
which vent termination zone is appropriate for your installa-
tion and fuel type, then adjust the stove restrictor plate to the
corresponding position as shown in Figure 7, page 9.
35 Ft.
(10.67 m)
25 Ft.
(7.62 m)
2 Ft.
(16 cm)
VERTICAL RUN
Minimum
Vertical
Termination
8 Ft.
(2.43 m)
45°
Elbow
Up
HORIZONTAL RUN
C