Hitachi FD2 1590 Water Pump User Manual


 
Performance Chart - 1590
311879F 41
Performance Chart - 1590
Test Conditions: Pump tested in water with inlet submerged
Fluid Pressure Curves
A
at 120 psi (0.7 MPa, 7 bar) operating air pressure
B
at 100 psi (0.7 MPa, 7 bar) operating air pressure
C
at 70 psi (0.48 MPa, 4.8 bar) operating air pressure
D
at 40 psi (0.28 MPa, 2.8 bar) operating air pressure
T
o find Fluid Outlet Pressure
(
psi/MPa/bar) at a specific fluid flow (gpm/lpm) and
o
perating air pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2
. Follow vertical line up to intersection with selected
operating air pressure curve.
3
. Follow left to scale to read fluid outlet pressure.
Air Consumption Curves
A at 120 psi (0.7 MPa, 7 bar) operating air pressure
B at 100 psi (0.7 MPa, 7 bar) operating air pressure
C at 70 psi (0.48 MPa, 4.8 bar) operating air pres-
sure
D at 40 psi (0.28 MPa, 2.8 bar) operating air pres-
sure
To find Pump Air Pressure
(scfm or m
3
/min) at a specific fluid flow (gpm/lpm)
and operating air pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Read vertical line up to intersection with selected
operating air pressure.
3. Follow left to scale to read air consumption.
20
40
60
80
100
120
Fluid Outlet Pressure
0
(0.84, 8.4)
(0.7, 7)
(0.55, 5.5)
(0.41, 4.1)
(0.28, 2.8)
(0.14, 1.4)
psi (MPa, bar)
20
40
60
80
100
120
0
(0.84, 8.4)
(0.7, 7)
(0.55, 5.5)
(0.41, 4.1)
(0.14, 1.4)
140
(0.96, 9.6)
(0.28, 2.8)
140
(0.96, 9.6)
20
Air Consumption
Fluid Flow
gpm (lpm)
scfm (m
3
/min)
Fluid Flow
gpm (lpm)
(75)
40
(151)
60
(227)
80
(302)
100
(378)
120
(454)
20
(75)
40
(151)
60
(227)
80
(302)
100
(378)
120
(454)
TI8738A
TI8742A
TI8742A
TI8739A