High End Systems SHOWGUN Indoor Furnishings User Manual


 
CHAPTER 5
Maintenance and Troubleshooting
SHOWGUN
®
User Manual 47
Calibrate the flags
5. Connect one end of a
harness to a flag of the
dimmer motor and the other
to the corresponding header
on the 2-phase board (see
page 45). You can connect
and home one flag or a pair
of flags at the same time.
6. Power up the fixture. Unlock the Menu system by pressing Menu button for a few seconds
until the display goes to the 2-line format.
7. Use the left and right arrows to scroll to the Test option. Press Enter to select.
8. Use the up and down
arrows to scroll to SETUP
MOTORS
. Press Enter to
select. Use arrows to scroll
to YES and press Enter to
select. Flags will energize
against the standoffs.
9. Using a 2 mm hex key,
loosen the set screw at the
base of the flag.
10. Adjust each flag vertically to
the tickmark on the inside
standoff.
Tick marks for
vertical flag
adjustment