CHAPTER 2
Setup and Configuration
SHOWGUN
®
User Manual 11
Connecting to the Link
To link one or more fixtures to a DMX controller:
1. Connect the male XLR connector of a DMX Data cable to the controller’s DMX Data Out
connector.
2. Connect the Data cable’s female XLR connector to the Data In connector of the first (or
next) fixture on the DMX link.
3. Continue linking the remaining fixtures connecting a cable from the Data Out connector of
each fixture to the Data In connector of the next fixture on the link.
4. Terminate the link by installing a 120 ohm, 1/4 watt (minimum) terminator in the fixture’s
Data Out (female) cable connector in the last fixture on each DMX link. A terminator on the
last fixture of the link prevents data reflection, which can corrupt the data communication
on the link.
1
2
0
Ω
1
2
3
4
5
To construct a terminator:
1. Disassemble a male 5-pin XLR connector.
2. Solder a 120 ohm resistor, minimum of 1/4 watt, between Pin 2 and P
3. Reassemble the XLR connector.
Powering On the Fixture
WARNING:
This equipment is designed for connection to a branch circuit
having a maximum overload protection of 20 A.
CAUTION:
Do not power on the fixture until verifying that the line cord
cap is suitable for the power source in your location. For more
information, see
Installing a Power Cord Cap on page 7.
To power on the SHOWGUN fixture, simply connect it to a 200V-240V AC power source.
Fixture Homing
Once the SHOWGUN fixture is connected to a power source, it automatically begins a homing
procedure to verify that the major functions of the fixture.