Heat & Glo LifeStyle XLR-PB-CE Indoor Fireplace User Manual


 
Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. J • 5/1220
D. MantelandWallProjections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specied. Framing or nishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).
Figure5.3 ClearancesToCombustible/Non-Combustible
MantelsOrOtherCombustibles/Non-Combust-
iblesAboveAppliance.
Mantels(Combustible/Non-Combustible)
Figure5.4Non-CombustibleMantelLegorWallProjections
(Acceptableonbothsidesofopening)
UNLIMITED
TOP VIEW
18 cm
8 cm
MINIMUM
36 cm
MIN.
30 cm
MAX.
1,3 cm
Thick Wall
Sheathing
MEASUREMENT
FROM TOP OF
FIREPLACE
OPENING
Note:For non-combustible replace nish material (marble,
stone, etc) specications refer to Section 13.C.
MantelLeg(Combustible/Non-Combustible)
8,90 cm
2,5 cm
AIR SPACE
NON-COMBUSTIBLE
BOARD SHIPPED
WITH APPLIANCE
2,5 cm
Figure5.6Non-CombustibleZone
Note:AIR SPACE denoted in Figure 5.6 is dened by the
nailing tabs and metal standoffs.
Note: Factory installed non-combustible board may only
be replaced with HHT product code SUPERM-60 material
and must be fully replaced in its entirety.
Figure5.5 FrontSideFinishingDetail
2,5 cm
FRAMING
1,2 cm FACTORY-SUPPLIED
NON-COMBUSTIBLE BOARD
NAILING TAB