Heat & Glo LifeStyle Exclaim-50 Indoor Fireplace User Manual


 
30
ROOM ABOVE (non-insulated ceiling)
ATTIC ABOVE (insulated ceiling)
B
A
Ceilng firestop from
bottom
Ceiling firestop from
top
Note:
Use same dimensional lumber for framing
ceiling firestop and joists.
 
Install a ceiling restop whenever chimney penetrates
ceiling/oor.
Mark and cut an opening in ceiling as shown in
Figure 8.5.
Frame the opening with the same size lumber used in
the ceiling joists.
Nail the ceiling restop to the bottom of the ceiling joists
when there is a room above.
Use an attic insulation shield if the ceiling is insulated.
The ceiling restop may then be attached above or below
the joists.

CAUTION! Risk of Fire! Ceiling restops must be used
whenever the chimney penetrates a ceiling/oor.
Chase construction requires ceiling restops at each
oor or every 10 ft (3.05 m) of clear space.
The ceiling restop slows spread of re and reduces cold
air inltration.
WARNING! Risk of Fire! DO NOT seal area between
restop opening and chimney pipe except where they
enter the attic or leave the warm air envelope of the
home (use 600° F sealant).
Heat & Glo • EXCLAIM-50 • 4013-041 • Rev AA • 7/12

in. mm in. mm
FS538 17 432 17 432
FS540 17 432 26 660