WARNING! Risk of Fire! You must comply with all minimum air space clearances to combustibles as specied in Fig-
ure 6.2. DO NOT pack required air spaces with insulation or other materials.
Heat & Glo • EXCLAIM-50 • 4013-041 • Rev AA • 7/12
 
0 in.
from floor
Attic
Insulation
Shield
Ceiling Firestop
(ceiling)
(roof)
(attic)
(ceiling)
2 in. min.
(51 mm)
2 in. min.
(51 mm)
2 in. min.
(51 mm)
2 in. min.
(51 mm)
2 in. min.
(51 mm)
2 in. min.
(51 mm)
Must have 2 in. (51 mm)
minimum clearance
to header
Ceiling Firestop
Offset/Return with
hanger straps
Storm Collar
Roof Flashing
0 in. to level
of standoffs
1-1/2 in. (38mm) from
side of appliance
(except at nailing flanges
where it is 1/2 in. (13 mm)
1-1/2 in. (38mm) from
back of appliance