Heat & Glo LifeStyle Exclaim-50 Indoor Fireplace User Manual


 
11


 

When they reach bottom of grate
Homeowner
WARNING! Risk of Fire! Ashes could contain hot em-
bers.
Place ashes in a metal container with a tight-tting lid.
The closed container should be placed on a non-
combustible oor or on the ground, well away from all
combustible materials, pending nal disposal.
If the ashes are disposed of by burial in soil or otherwise
locally dispersed, they should be retained in the closed
container until all cinders have thoroughly cooled.

At least twice a year during heating season
or as recommended by a certied chimney sweep
Certied chimney sweep
WARNING! Risk of Fire! Ignited creosote is extremely
HOT. Prevent creosote buildup.
Refer to Figure 3.1 to remove/reinstall termination caps.

When wood is burned slowly, it produces tar and other
organic vapors, which combine with expelled moisture to
form creosote. The creosote vapors condense in the rela-
tively cool chimney ue of a slow-burning re. As a result,
creosote residue accumulates on the ue lining. When
ignited this creosote makes an extremely hot re.
WARNING! Risk of Fire! A chimney re can permanently
damage your chimney system and nearby structures.
In the event of a chimney re, Hearth & Home Technolo-
gies Inc. recommends
replacement of the chimney, and
inspection of the adjacent structure to the provisions of
NFPA Level III inspection criteria.
The chimney shall be inspected at least twice a year
during the heating season to determine when a creosote
buildup has occurred.
When creosote has accumulated it shall be removed to
reduce the risk of a chimney re.
Heat & Glo • EXCLAIM-50 • 4013-041 • Rev AA • 7/12
Chimney
Remove 4 screws
and lift top pan off.
Cap
Slip
Section
ST1175
Square Termination Cap
Cap
Remove screws,
lift top cover.
Top Cover
TR11/TR11T
Round Termination Cap
TCT1175
Terra Cotta
Termination Cap
Remove 2 screws from
the front and back and
lift the top off.
1. REMOVE (8) SCREWS
2. LIFT TOP
TOP
TOP
SCREW
SCREW
DT SERIES