Heat & Glo LifeStyle ESCAPE-I35-C Heating System User Manual


 
Heat & Glo • Escape-I35-C, Escape-I30-C • 2201-901 Rev. H • 5/12 40
J. Air Shutter Setting
Air shutter settings should be adjusted by a quali ed ser-
vice technician at the time of installation. The air shutter is
set at the factory for minimum vertical vent run. Adjust air
shutter for longer vertical runs. See Figure 12.3.
NOTICE: If sooting occurs, provide more air by opening
the air shutter.
Figure 12.3 Air Shutter
Figure 12.2 Fixed Glass Assembly
I. Fixed Glass Assembly
WARNING! Risk of Asphyxiation! Handle xed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
DO NOT strike, slam or scratch glass.
DO NOT operate replace with glass removed, cracked,
broken or scratched.
Replace as a complete assembly.
Removing Fixed Glass Assembly
• The glass assembly fastens to the replace in four
places. The fastening mechanisms are spring-loaded
glass latches. An example of the glass latch is shown
in Figure 12.2.
To release glass assembly, pull the two top spring-loaded
latches forward and allow them to retract away from
the glass assembly. Slide the glass assembly outward
and downward until top of the glass frame will clear the
surround.
Replacing Fixed Glass Assembly
• Tilt glass assembly toward replace and slide glass
assembly downward to engage bottom latches. Verify
bottom latches are fully engaged and then fasten the
two top latches.
• Note that the extended glass latch tabs on the glass
frame are for the bottom glass latches.
Air Shutter Settings
NG LP
ESCAPE-I30-C 1/4 in. Full Open
ESCAPE-I35-C 1/4 in. Full Open
GLASS
ASSEMBLY
LATCHES
(BOTH BOTTOM
AND TOP)
AIR SHUTTER