Heat & Glo LifeStyle ESCAPE-I35-C Heating System User Manual


 
Heat & Glo • Escape-I35-C, Escape-I30-C • 2201-901 Rev. H • 5/12 10
J. Before Lighting Fireplace
Before operating this replace for the rst time, have a
quali ed technician:
• Verify all shipping materials have been removed from
inside and/or underneath the rebox.
Review proper placement of logs, ember material and/or
other decorative materials.
• Check the wiring.
• Check the air shutter adjustment.
• Ensure that there are no gas leaks.
Ensure that the glass is sealed and in the proper position
and that the integral barrier is in place.
WARNING! Risk of Fire/Asphyxiation! DO NOT oper-
ate replace with xed glass assembly removed.
This replace has an Intelli re Plus
TM
ignition system.
Figure 2.7. Module Reset Switch
MODULE RESET SWITCH
5. Module Reset Switch
This module may lock-out under certain conditions.
When this occurs, the appliance will not ignite or
respond to commands. The module will go into lock-out
mode by emitting three audible beeps, then continuously
displaying a RED/GREEN error code at its status
indicator LED.
Check battery tray. Remove batteries if installed.
Batteries should only be installed for use during power
outages. See Section H.
Locate the module reset switch. (See Figure 2.7).
Set the module reset switch to the RESET position.
• Wait ve (5) minutes to allow possible accumulated gas
to clear.
Set the module reset switch to ON.
Start the appliance.
WARNING! Risk of Explosion! DO NOT press the mod-
ule reset switch more than one time within a ve minute
time period. Gas may accumulate in rebox. Call a quali-
ed service technician.
Nine Hour Safety Shutdown Feature
This appliance has a safety feature that automatically
shuts down the replace after 9 hours of continuous
operation without receiving a command from the
RC300 remote.