Santa Fe Pellet Stove
*L Exception for Horizontal Installations:
USA INSTALLATIONS: If optional Cast Base is installed use
a non-combustible oor protector extending under unit and to
the sides, front and back of unit as shown in Floor Protection
Diagram. Measure front distance (M) from the surface of the
glass door.
If Cast Base is not installed, the non-combustible oor protec-
tor must be 1/4 inch (6mm) minimum thickness (“k” value =
0.84).
A
non-combustible oor protection extending beneath the
ue pipe is recommended
with horizontal venting or under
the top vent adapter with vertical installation. Figure 9.2.
CANADA INSTALLATIONS: A
non-combustible oor pro-
tection extending beneath the ue pipe is r
equired
with
horizontal venting or under the top vent adapter with vertical
installation.
Must extend 2 inches (51mm) beyond each
side of pipe (shaded area)
C. Hearth Pad Requirements (UL and ULC)
Use a non-combustible oor protector, extending beneath
appliance and to the front, sides and rear as indicated.
Measure front distance “M” from the surface of the glass
door.
Hearth Pad Requirements
Inches Millimeters
K
Sides 2 51
L*
Back 2 51
M
Front 6 152
L*
K
K
M
Figure 9.2