Recommended operating procedures
Ignite the fire in the appliance with the variable speed
control switch in an "ON" position. The fan will automati-
cally turn on when the temperature sensor switch closes
at approximately 110 degrees Fahrenheit. Heated air
should be delivered at the outlet grille. The fan will con-
tinue to operate after the appliance is turned OFF until the
sensor switch opens.
Various conditions (such as appliance model, type of
appliance installation, outside air temperature vs. inside
air temperature) can contribute to the length of the time
the blower remains on after the appliance is turned OFF.
The blower can be turned off manually with the speed
control switch.
Plug the blower cord into the FAN outlet on the junction
box. Refer to Figure 8.29, on the next page.
Push excess wires neatly towards the rear of the appliance.
Slide the blower into the bracket as indicated. Ensure
the blower is pushed back into the bracket to allow the
replacement of the lower access door. The magnet strips
located on the blower feet are designed to hold the blower
in place. See Figure 8.28.
Figure 8.28
Attach the ground clip to the control panel. Attach the
ground wire extension to the ground clip. Attach the the
blower ground wire to the ground wire extension.
Figure 8.29
Reattach the switch bracket with the two screws previously
removed.
Connect the variable speed control and the temperature
sensor switch to the short lead wires of the junction box by
plugging in the male and female connectors. See Figure
8.31, on the next page).
Plug appliance in. Turn the 110-120 VAC service "ON" at
the circuit breaker and turn the speed control switch to the
"ON" position.