9. Install the cover plate removed from the rear of the
appliance to the top of the appliance with the screws
previously removed. (Figure 8.13).
10. Install the new solid top.
Figure 8.13
F. Shutter Adjustment
The shutter is located on the underside of the burner, on
the burner neck (see Figure 8.14).
G. Installing the Vent Restrictor
The vent restrictor plate must be installed before installing
the baffle.
On the top of inside firebox for top vent ,on back of firebox
for rear vent, loosen the three screws out about 1/8 in.
Place the vent restrictor plate over the the screws and
slide into locking position. Retighten the screws. (See
Figure 8.15.)
Figure 8.14
For vertical venting above 6 ft. a vent restrictor is required.
After installing the vent restrictor plate, remove the inner
rings as needed for proper flame height. (Refer to Figure
8.16.)
Figure 8.15
Figure 8.16
Top Vent
Top Vent
Rear Vent
Rear Vent