Hearth and Home Technologies NorthStar-NT Indoor Fireplace User Manual


 
Page 40
Heat & Glo • NorthStar EPA Fireplace • 480-1081C
September 1, 2008
September 1, 2008
September 1, 2008
Fascia
OuterCan
Flange
Ember Strip (Seal gap with
High temp, noncombustible
sealant able to withstand
300°)
Tile or
Marble
Minimum2-1/4in.(57mm)CementBoard
orequivalent,(ortwo1/2in.pieces)
and"k"value=0.49.Micore300
Minimum20in.(508mm)infrontand
8 in. (203mm) on sides to fuel loading doors
Tile or
Marble
Combustible Floor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . .
Fascia
Outer
Can
Flange
Ember Strip (Seal gap
with high temp,
noncombustible sealant
able to withstand 300°)
TileorMarble
Minimum2-1/4in.
57mm) Cement
Board or equivalent,
(ortwo1/2in.pieces)
and"k"value=0.49.
Micore300
Min20in.(508mm)infrontand8in.
(203mm) on sides to fuel loading doors
Combustible
Floor
2 x 4
2 x 4
3/4in.
(19mm)
Plywood
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fascia
Outer
Can
Flange
Ember Strip
(Seal gap with
noncombustible
sealant)
TileorMarble
Minimum2-1/4in.(57mm)
Cement Board or equivalent,
(ortwo1/2in.pieces)and
"k"value=0.49.Micore300
Min20in.(508mm)infrontand8in.
(203mm) on sides to fuel loading doors
Combustible Floor
2 x 4
2 x 4
3/4in.
(19mm)
Plywood
Non-combustible
framing materials
Figure 40.1 Fireplace and Hearth Extension Flush on the Floor.
Figure 40.2
Fireplace and Hearth Extension Flush on Floor but on Raised Platform
Figure 40.3
Raised Hearth Extension to Bottom of Fascia