Hearth and Home Technologies NorthStar-NT Indoor Fireplace User Manual


 
September 1, 2008
September 1, 2008
Heat & Glo • NorthStar EPA Fireplace • 480-1081C
Page 13
Fire Risk
Donotapplycombustiblenishingmaterials
overanypartofthefrontofthisreplace.
Themetalreplace facemayonlybe
covered with noncombustible materials
such as ceramic tile, brick, or stone.
Do not cover or block any cooling air
slots.
The decorative fascia must be removable
for future serviceability of the Automatic
Combustion Control.
WARNING
Fire Risk
Comply with all minimum clearances speci-
ed.
Aminimum 1/2 in. (13mm)air clearance
must be maintained at the back and 1
in. (25mm) to the sides of the fireplace
assembly.
Chimney sections at any level require a 2
in. (51mm) minimum air space clearance
between the framing and chimney section.
WARNING
D. Electrical Access and Wiring Diagram
NOTE: The manual override switch, rheostat
speed control and cover plate are supplied. You
willneedtosupply:14-3wirewithground;14-2
wire with ground; standard wall mount junction
box; and wire nuts.
1. Remove junction box cover plate on the
bottomrightsideofthereplace.
2. Thread the 14-3 with ground wire through
the opening with the strain relief on the cover
plate.
3. Matchcolorstowireharness,(redtored,
white to white, etc) and secure with wire
nuts.
NOTE: Wiring for fans must be done before
framed enclosure is completed. If using a
Heat Zone kit, it also must be installed before
enclosure is complete.
Figure 13.2 Fan Wiring Diagram
14-2 w/ground
Standard wall mount with
Junction Box
14-3 w/ground
WIRE NUT
WHITE
GREEN
BLACK
BLACK
RED
WHITE
Match colors to wire
harness (red to red,
white to white, etc) and
secure with a wire nut
Incoming Power
(110V)
Power to the Fireplace
Snap Disc
bypass switch
Suggestions:
1. Insulate chase.
2. Finishchasewallswithdrywall5/8in.(16mm)TypeX
face tape.
3. Alldimensionsaretonishedwallsandceilings.
Figure 13.1 Sheetrocked Chase
Fire Risk
• Maintainclearances.
Use only non-combustible material below
standoffs, material such as cement board
is acceptable.
WARNING
• Framingornishingmaterialusedonthefront
of, or in front of, the appliance closer than the
minimums listed, must be constructed entirely of
noncombustible materials (i.e., steel studs, concrete
board, etc.).