Home Automation 20A00-1 Home Security System User Manual


 
Page 51
OMNI II SPECIFICATIONS
Size: Controller: 13 W x 13 H x 4.5 D
Console: 4.6 W x 4.5 H x 1.2 D
Weight: Controller: approx. 10 lb.
Console: approx. 0.5 lb.
Operating 32 - 122 degrees F (0 - 50 degrees C)
Ranges: 10 - 95 % relative humidity, non-condensing
Power: 120 VAC, 60 Hz, 60 watts
Transformer: 24 VAC, 1.67 amps, 40 VA
Battery: Rechargeable Lead-Acid, 12 volts, 7 amp-hour
Device Fuse: Polyfuse: 1.35 A
Horns Fuse: Polyfuse: 1.35 A
Battery Fuse: Polyfuse: 4.00 A
Polyfuses are permanent fuses that do not need replacement.
Nominal Voltage: 10 - 13.7 VDC, 0.5 V max. peak to peak ripple
Low Voltage Cut Out: approx. 9 VDC
Typical Current Consumption at Nominal Voltage:
Controller: 135 mA
Console: backlight off - 35 mA; backlight on - 100 mA
Controller Maximum Group Current Outputs:
Devices: AUX 12 VDC, SWITCH 12 VDC, CONSOLE, and OUTPUTS 1 - 8: 1 A
Horn: INT HORN and EXT HORN: 1 A
Controller Maximum Individual Current Outputs:
Devices: (Do not exceed 1 A total)
AUX 12 VDC 1 A
SWITCH 12 VDC 1 A
CONSOLE 1 A
OUTPUTS 1 - 8 100 mA
For 24-Hour Battery Standby Time, the following must be observed: (See Figure 15)
Controller Maximum Group Current Outputs (applies to residential and commercial):
Devices: AUX 12 VDC, SWITCH 12 VDC, CONSOLE, and OUTPUTS 1 - 8: 250mA
Horn: INT HORN and EXT HORN: 300mA