Home Automation 20A00-1 Home Security System User Manual


 
Page 39
REPORT OPEN/CLOSE
The communicator can be setup to send an opening and a closing report by user code. Whenever the system is disarmed the
communicator will send an opening report to the central station. When the system is armed, the communicator will send a closing
report to the central station.
REPORT OPEN/CLOSE: 0
0=NO 1=YES
To enable the communicator to send opening and closing reports to the central station, select the 1 (YES) key.
AUTOMATIC TEST TIME
The communicator CAN be setup to automatically send a test code to the central station on a periodic basis. AUTOMATIC
TEST TIME is used to set the time and days of the week of the test, and the TEST CODE specifies the code that will be
transmitted for the test.
AUTOMATIC TEST TIME:
-- NEVER #=CHNG
To disable the automatic test, press the ' # ' key and then 0 for Never, and ' # '.
TEST CODE: 98
0-FF
ALARM CODES (4/2 and 3/1 Formats)
Press the down arrow (") to advance to the next ZONE ALARM CODE. Press the up arrow (!) to go to the previous ZONE
ALARM CODE. To change an alarm code, enter two digits for 4/2 format, or one digit when using 3/1 format, then press the ' # '
key.
Enter the 2 digit alarm code (1 digits if using 3/1 format) and press ' # '. To enter the digits B-F, first press the OFF key, then
press the 1-5 key respectively (i.e. B1 = OFF 1 1 # and CB = OFF 2 OFF 1 #).
The various alarm codes are sent when the indicated alarm zone is tripped. Each alarm code must be two digits long for 4/2
format (01-FF), 1 digit for 3/1 format (1-F).
To disable the digital communicator for a specific zone, set the alarm code to 0 or 00. The digital dialer will
not report when this zone is tripped.
ZONE 1 ALARM CODE: 01
0-FF
THROUGH
USER 16 CLOSE CODE: 76
0-FF