SYSTEM POWER UP PROCEDURE
1. Carefully review hookups to the zones, grounds, sounders, and consoles.
2. Disconnect 1 lead of both the interior and exterior sounders.
NOTE: Follow this power up procedure to verify proper operation of the power supply, battery charger, and low voltage cut
out relay.
3. The positive lead to the battery should be disconnected at this time. Make sure that the red battery wire is not touching
anything.
4. Plug in the power transformer.
- The AC ON LED should illuminate.
- Within one minute, the STATUS LED should begin blinking at a rate of 1 blink per second. This indicates that the
Omni II processor and software are working.
- The PHONE LED should be OFF (if all telephones are on-hook and the RJ31X jack is properly connected.
5. Unplug the power transformer to kill the system. Connect the red battery wire to the + (positive) battery terminal. The
system should not
start.
6. Plug in the power transformer. The system should start.
7. Unplug the power transformer. The system should continue to run on the battery (the STATUS LED will continue to flash).
8. Plug the transformer back in and secure it to the outlet.
CONSOLE CHECK OUT
1. The console(s) should be operating. Press ' * ' to silence the trouble beeper if it is beeping. Press OFF, 1, 1, 1, 1 (or the
current User code) if the alarm is tripped. If the consoles are not operating properly, make sure that no two consoles have the
same address, and check the wiring.
2. With all doors and windows closed and all motion detectors secure, the bottom line of the display should read SYSTEM OK.
If there are any trouble indications that occurred during installation, press ' * ' to acknowledge them and silence the beeper.
3. Set the time and date by pressing the 9 key. Enter the Master Code, then press the 2 key. Enter the time on the keypad, then
the DATE (enter date as 6 characters: January 1, 00 as 010100).
4. The console should now show the time and date on the top line and "SYSTEM OK" on the bottom line.
TELEPHONE CHECK OUT
1. Verify that the Telephone Company surge arrestor is properly grounded.
2. Verify that the incoming telephone lines are run to the surge arrestor first, then from the surge arrestor to the RJ31X jack,
then from the RJ31X jack to the house phones.
3. The PHONE LED, on the controller, should be off when the phones are hung up.
4. Pick up an in-house phone, wait about 1 second, then press the ' # ' key. You should hear the Voice menu on the phone. If
not, check to see that the RJ31X jack is properly wired and connected to the controller. There should be no interference from
the Telephone Company while the menu is being read over the phone.