Home Automation 20A00-1 Home Security System User Manual


 
Page 47
DATE DISPLAY
This allows you to choose between MONTH/DAY and DAY/MONTH date format.
DATE DISPLAY: 1
1=MMDD 2=DDMM
AC POWER FREQUENCY
Set this to the appropriate AC Powerline Frequency.
AC POWER FREQUENCY: 1
1=60HZ 2=50HZ
DEAD LINE DETECT
NOTE: To disable Omni II from detecting a dead line, set this item to '0'; otherwise adjust only under direction of HAI.
This item adjusts the threshold that is used to determine when the phone line goes dead.
DEAD LINE DETECT: 8
0-15 0=DISABLE
OFF HOOK DETECT
NOTE: Adjust only under direction of HAI.
This item adjusts the threshold that is used to determine when the phone line is going off hook.
OFF HOOK DETECT: 69
20-250
PICKUP AFTER HANGUP
This item is used to disable Omni II from picking up the phone line after the called party hangs up the line.
PICKUP AFTER HANGUP: 1
0=NO 1=YES
Currently, after the called party or the called party's answering machine hangs up the phone line, Omni II picks up the line and
make its "Beep". If you wish to turn the Pickup After Hangup OFF, press 0 then ' # '. To turn it back On, press 1 then ' # '.
The default setting for Pickup After Hangup is Yes.
CLOCK ADJUSTMENT
If the clock on an Omni II is running faster or slower than the actual time, you can have the Omni II automatically compensate up
to 29 seconds per day. The Omni II will add or subtract the selected amount of time daily.
CLOCK ADJUSTMENT: 30
1-59=-29 TO +29 SEC/DAY
Enter 1-29 to subtract 1-29 seconds. Enter 31-59 to add 1-29 seconds. Enter 30 for no adjustment to the clock.
The default setting is 30.