SERIAL 1 FUNCTION
The "Serial 1 Function" selects the communication protocol used for the built-in serial interface (J1 Serial) on the Omni II
controller. Select the function for the built-in serial interface from the list. Use the arrow keys to select the function then press
the ' # ' key.
FUNCTION TYPES NUMBER DESCRIPTION
OMNI-LINK 3 Serial communication using the Omni-Link protocol
PRO-LINK 4 Serial communication using the Pro-Link protocol
SERIAL 2 RATE
"Serial 2 Rate" selects the baud rate used when a Serial Interface Module is added to the Omni II system. If a Serial Interface
Module is installed, select its baud rate then press the ' # ' key.
BAUD RATE NUMBER
75 baud 1
150 baud 2
300 baud 3
600 baud 4
1200 baud 5
2400 baud 6
4800 baud 7
9600 baud 8 (default)