COOLING PERFORMANCE DATA
GSH130363AF
EXPANDED PERFORMANCE DATA
COOLING OPERATION
MODEL: GSH130363A* / ARUF49-00*-1* / ARUF36421A*
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 596367715963677159636771596367715963677159636771
MBh 30.3 31.4 34.4 - 29.6 30.7 33.6 - 28.9 30.0 32.8 - 28.2 29.2 32.0 - 26.8 27.8 30.4 - 24.8 25.7 28.2 -
S/T 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.84 0.70 0.49 - 0.87 0.72 0.50 - 0.90 0.75 0.52 - 0.91 0.76 0.52 -
DT 16 14 11 - 17 14 11 - 17 14 11 - 17 14 11 - 16 14 11 - 15 13 10 -
1350 KW 2.21 2.26 2.34 - 2.40 2.45 2.54 - 2.56 2.62 2.71 - 2.70 2.77 2.87 - 2.83 2.89 3.00 - 2.93 3.00 3.11 -
AMPS 5.5 5.6 5.8 - 5.9 6.0 6.2 - 6.3 6.5 6.7 - 6.8 6.9 7.1 - 7.2 7.3 7.5 - 7.6 7.7 8.0 -
HI PR145156165 - 163175185 - 185199211 - 211227240 - 237255270 - 262282298 -
LO PR 66 70 76 - 69 74 81 - 72 77 84 - 76 81 88 - 79 84 92 - 82 87 95 -
MBh 29.9 31.0 33.9 - 29.2 30.2 33.1 - 28.5 29.5 32.3 - 27.8 28.8 31.6 - 26.4 27.4 30.0 - 24.5 25.3 27.8 -
S/T 0.76 0.63 0.44 - 0.78 0.66 0.45 - 0.80 0.67 0.47 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.87 0.73 0.50 -
DT 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 16 14 11 -
70 1217 KW 2.20 2.25 2.33 - 2.38 2.44 2.52 - 2.54 2.60 2.70 - 2.69 2.75 2.85 - 2.81 2.88 2.98 - 2.91 2.98 3.09 -
AMPS 5.4 5.6 5.7 - 5.8 6.0 6.2 - 6.3 6.5 6.7 - 6.7 6.9 7.1 - 7.1 7.3 7.5 - 7.5 7.7 7.9 -
HI PR144155164 - 162174184 - 184198209 - 210226238 - 236254268 - 260280296 -
LO PR 65 69 76 - 69 73 80 - 72 76 83 - 75 80 87 - 79 84 92 - 81 87 95 -
MBh 27.6 28.6 31.3 - 26.9 27.9 30.6 - 26.3 27.2 29.9 - 25.6 26.6 29.1 - 24.4 25.3 27.7 - 22.6 23.4 25.6 -
S/T 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.84 0.70 0.48 -
DT 18 15 12 - 18 15 12 - 18 15 12 - 18 16 12 - 18 15 12 - 17 14 11 -
1050 KW 2.14 2.19 2.26 - 2.32 2.37 2.46 - 2.48 2.53 2.62 - 2.62 2.68 2.77 - 2.73 2.80 2.90 - 2.84 2.90 3.01 -
AMPS 5.3 5.4 5.6 - 5.7 5.8 6.0 - 6.2 6.3 6.5 - 6.5 6.7 6.9 - 6.9 7.1 7.3 - 7.3 7.5 7.7 -
HI PR140151159 - 157169178 - 178192203 - 203219231 - 229246260 - 253272287 -
LO PR 63 67 73 - 67 71 78 - 69 74 81 - 73 78 85 - 76 81 89 - 79 84 92 -
MBh 30.831.734.436.930.131.033.636.029.430.332.835.228.7
29.5
32.034.327.228.130.432.625.226.028.130.2
S/T 0.900.800.610.390.930.830.630.410.950.850.650.420.99
0.88
0.67 0.43 1.00 0.91 0.69 0.45 1.00 0.92 0.70 0.45
DT 19 17 14 10 19 18 14 10 19 18 14 10 19
18
15 10 19 17 14 10 17 16 13 9
1350 KW 2.23 2.28 2.36 2.44 2.42 2.47 2.56 2.65 2.58 2.64 2.74 2.83 2.73
2.79
2.89 3.00 2.85 2.92 3.02 3.13 2.96 3.03 3.14 3.25
AMPS5.55.65.86.05.96.16.26.56.46.56.77.06.8
7.0
7.2 7.4 7.2 7.4 7.6 7.9 7.6 7.8 8.0 8.3
HI PR147158167174165177187195187201213222213
229
242253240258273284265285301314
LO PR 66 71 77 82 70 75 81 87 73 77 85 90 76
81
89 95 80 85 93 99 83 88 96 103
MBh 30.431.333.936.329.730.633.135.529.029.832.334.628.3
29.1
31.533.826.827.629.932.124.925.627.729.7
S/T 0.860.770.580.370.890.800.600.390.910.820.620.400.94
0.84
0.64 0.41 0.98 0.88 0.66 0.43 0.99 0.88 0.67 0.43
DT 20 18 15 10 20 18 15 10 20 18 15 10 20
19
15 10 20 18 15 10 19 17 14 10
75 1217 KW 2.22 2.27 2.35 2.43 2.40 2.46 2.54 2.63 2.57 2.63 2.72 2.82 2.71
2.78
2.87 2.98 2.83 2.90 3.01 3.11 2.94 3.01 3.12 3.23
AMPS5.55.65.86.05.96.06.26.46.46.56.76.96.8
6.9
7.1 7.4 7.2 7.3 7.6 7.8 7.6 7.7 8.0 8.3
HI PR146157166173163176186194186200211220212
228
241251238256271282263283299312
LO PR 66 70 76 81 70 74 81 86 72 77 84 89 76
81
88 94 80 85 92 98 82 88 96 102
MBh 28.028.931.233.527.428.230.532.826.727.529.832.026.1
26.9
29.131.224.825.527.629.623.023.625.627.5
S/T 0.830.740.560.360.860.770.580.370.880.790.600.380.91
0.81
0.62 0.40 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41
DT 20 19 15 11 21 19 16 11 21 19 16 11 21
19
16 11 20 19 15 11 19 18 14 10
1050 KW 2.16 2.21 2.28 2.36 2.34 2.39 2.48 2.56 2.50 2.56 2.65 2.74 2.64
2.70
2.80 2.90 2.76 2.82 2.92 3.03 2.86 2.93 3.03 3.14
AMPS5.45.55.65.85.85.96.16.36.26.36.56.86.6
6.7
7.0 7.2 7.0 7.1 7.4 7.6 7.4 7.5 7.8 8.1
HI PR141152161167159171180188180194205214205
221
233243231249263274255275290303
LO PR 64 68 74 79 67 72 78 83 70 75 81 87 74
78
86 91 77 82 90 95 80 85 93 99
Shaded area is ACCA (TVA) conditions IDB: Entering Indoor Dry Bulb Temperature KW=Total system power AMPS=outdoor unit amps (comp.+fan)