Goodmans GSH 13 SEER - 3 Phase Split System Heat Pump Heat Pump User Manual


 
7
COOLING PERFORMANCE DATA
GSH130363AE
EXPANDED PERFORMANCE DATA
COOLING OPERATION
MODEL: GSH130363A* / ARUF49-00*-1* / ARUF36421A*
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 596367715963677159636771596367715963677159636771
MBh 34.3 35.5 38.9 - 33.5 34.7 38.0 - 32.7 33.9 37.1 - 31.9 33.1 36.2 - 30.3 31.4 34.4 - 28.1 29.1 31.9 -
S/T 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.81 0.67 0.47 - 0.83 0.70 0.48 - 0.87 0.72 0.50 - 0.87 0.73 0.51 -
Delta T 17 14 11 - 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 16 14 10 -
1434 KW 2.38 2.43 2.50 - 2.56 2.61 2.69 - 2.71 2.77 2.86 - 2.85 2.91 3.00 - 2.96 3.03 3.12 - 3.06 3.13 3.23 -
AMPS 7.7 7.8 8.1 - 8.2 8.4 8.7 - 8.9 9.1 9.4 - 9.5 9.7 10.0 - 10.1 10.3 10.7 - 10.7 10.9 11.3 -
HI PR 140 151 160 - 158 170 179 - 179 193 204 - 204 220 232 - 230 247 261 - 254 273 288 -
LO PR 63 67 73 - 67 71 77 - 69 74 81 - 73 77 85 - 76 81 89 - 79 84 92 -
MBh 33.3 34.5 37.8 - 32.5 33.7 36.9 - 31.7 32.9 36.1 - 31.0 32.1 35.2 - 29.4 30.5 33.4 - 27.3 28.3 31.0 -
S/T 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.45 - 0.80 0.66 0.46 - 0.83 0.69 0.48 - 0.83 0.70 0.48 -
Delta T 17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 18 15 12 - 16 14 11 -
70 1275 KW 2.36 2.41 2.49 - 2.54 2.59 2.67 - 2.69 2.75 2.83 - 2.83 2.89 2.98 - 2.94 3.00 3.10 - 3.04 3.11 3.21 -
AMPS 7.6 7.8 8.0 - 8.2 8.4 8.6 - 8.8 9.0 9.3 - 9.4 9.6 9.9 - 10.0 10.2 10.6 - 10.6 10.8 11.2 -
HI PR 139 150 158 - 156 168 177 - 177 191 202 - 202 217 230 - 227 245 258 - 251 270 285 -
LO PR 63 66 73 - 66 70 77 - 69 73 80 - 72 77 84 - 76 80 88 - 78 83 91 -
MBh 30.7 31.9 34.9 - 30.0 31.1 34.1 - 29.3 30.4 33.3 - 28.6 29.6 32.5 - 27.2 28.2 30.8 - 25.2 26.1 28.6 -
S/T 0.70 0.58 0.40 - 0.72 0.61 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.80 0.66 0.46 - 0.80 0.67 0.46 -
Delta T 18 15 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 15 12 - 17 14 11 -
1116 KW 2.31 2.36 2.43 - 2.48 2.53 2.61 - 2.63 2.68 2.77 - 2.76 2.82 2.91 - 2.87 2.93 3.02 - 2.97 3.03 3.13 -
AMPS 7.4 7.6 7.8 - 8.0 8.1 8.4 - 8.6 8.8 9.1 - 9.2 9.4 9.7 - 9.7 10.0 10.3 - 10.3 10.5 10.9 -
HI PR 135 145 153 - 151 163 172 - 172 185 196 - 196 211 223 - 220 237 251 - 244 262 277 -
LO PR 61 65 70 - 64 68 74 - 67 71 77 - 70 74 81 - 73 78 85 - 76 81 88 -
MBh 34.9 35.9 38.9 41.7 34.1 35.1 38.0 40.7 33.3 34.2 37.1 39.8 32.4
33.4
36.2 38.8 30.8 31.7 34.4 36.9 28.6 29.4 31.8 34.2
S/T 0.860.770.590.380.900.800.610.390.920.820.620.400.950.85 0.64 0.41 0.98 0.88 0.67 0.43 0.99 0.89 0.67 0.43
Delta T1918151020181510201815102018 15 10 19 18 15 10 18 17 14 9
1434 KW 2.40 2.45 2.52 2.60 2.58 2.63 2.71 2.80 2.73 2.79 2.88 2.97 2.87 2.93 3.03 3.12 2.99 3.05 3.15 3.25 3.09 3.16 3.26 3.37
AMPS 7.7 7.9 8.1 8.4 8.3 8.5 8.8 9.1 9.0 9.2 9.5 9.8 9.6 9.8 10.1 10.5 10.2 10.4 10.8 11.2 10.8 11.0 11.4 11.8
HI PR 142 153 161 168 159 171 181 189 181 195 206 214 206
222
234 244 232 250 263 275 256 276 291 304
LO PR 64 68 74 79 67 72 78 83 70 74 81 87 74 78 85 91 77 82 90 95 80 85 93 99
MBh 33.9 34.9 37.7 40.5 33.1 34.1 36.9 39.6 32.3 33.2 36.0 38.6 31.5
32.4
35.1 37.7 29.9 30.8 33.3 35.8 27.7 28.5 30.9 33.2
S/T 0.820.740.560.360.850.760.580.370.880.780.590.380.900.81 0.61 0.39 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41
Delta T2019151020191511201915112119 15 11 20 19 15 11 19 17 14 10
75 1275 KW 2.38 2.43 2.50 2.58 2.56 2.61 2.69 2.78 2.71 2.77 2.86 2.95 2.85 2.91 3.00 3.10 2.96 3.03 3.13 3.23 3.06 3.13 3.23 3.34
AMPS 7.7 7.8 8.1 8.4 8.2 8.4 8.7 9.0 8.9 9.1 9.4 9.8 9.5 9.7 10.0 10.4 10.1 10.3 10.7 11.1 10.7 10.9 11.3 11.7
HI PR 140 151 160 166 158 170 179 187 179 193 204 212 204
220
232 242 230 247 261 272 254 273 288 301
LO PR 63 67 73 78 67 71 77 83 69 74 81 86 73 77 85 90 76 81 89 94 79 84 92 98
MBh 31.3 32.2 34.8 37.4 30.5 31.4 34.0 36.5 29.8 30.7 33.2 35.6 29.1
29.9
32.4 34.8 27.6 28.4 30.8 33.0 25.6 26.3 28.5 30.6
S/T 0.790.710.540.350.820.740.560.360.840.760.570.370.870.78 0.59 0.38 0.91 0.81 0.61 0.39 0.91 0.82 0.62 0.40
Delta T2019151121191611211916112119 16 11 21 19 16 11 19 18 15 10
1116 KW 2.33 2.38 2.45 2.52 2.50 2.55 2.63 2.71 2.65 2.70 2.79 2.88 2.78 2.84 2.93 3.02 2.89 2.95 3.05 3.15 2.99 3.05 3.15 3.26
AMPS 7.5 7.6 7.9 8.1 8.0 8.2 8.5 8.8 8.7 8.9 9.2 9.5 9.3 9.5 9.8 10.1 9.8 10.1 10.4 10.8 10.4 10.6 11.0 11.4
HI PR 136 147 155 161 153 164 174 181 174 187 197 206 198
213
225 235 223 240 253 264 246 265 280 292
LO PR 61 65 71 76 65 69 75 80 67 72 78 83 71
75
82 87 74 79 86 92 77 81 89 95
Shaded area is ACCA (TVA) conditions IDB: Entering Indoor Dry Bulb Temperature KW=Total system power AMPS=outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and suction service valves.