Goodman Mfg GSX Air Conditioner User Manual


 
CONDENSING UNIT SPECIFICATIONS
6
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance
with all national and/or local electrical codes. Use copper wire only.
GSX130[18-60]1A*
(1)
Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
(2)
Maximum Overcurrent Protection Device: MUST use time delay fuses or HACR-type Circuit Breakers of the same size as noted.
NOTES:
* Always check the S&R plate for electrical data on the unit being installed.
* Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections.
* Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
* Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED
BY THE OUTDOOR UNIT NOT THE INDOOR COIL.
GSX130181A* GSX130241A* GSX130301A* GSX130361A*
Cooling Capacity, BTUH 18,000 24,000 30,000 36,000
Compressor
R.L. Amps 9.00 13.4 12.8 16.6
L.R. Amps 48.0 58.3 64.0 79.0
High Pressure Switch
Open 610 PSIG 610 PSIG 610 PSIG 610 PSIG
Close 420 PSIG 420 PSIG 420 PSIG 420 PSIG
Condenser Fan Motor
Horsepower 1/6 1/6 1/6 1/6
F.L. Amps 1.10 1.10 1.10 1.10
Liquid Line, Inches O.D.* 3/8" 3/8" 3/8" 3/8"
Suction Line, Inches O.D.* 3/4" 3/4" 3/4" 3/4"
Refrigerant Charge 120.0 116.0 129.0 131.0
Power Supply 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1
Minimum Circuit Ampacity
(1 )
12.3 17.9 17.1 21.9
Maximum Overcurrent Device
(2)
20 30 30 35
Electrical Conduit Size
Power Supply (Inches) 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4
Approxim ate Shipping Weight
178 178 180 197
GSX130421A* GSX130481A* GSX130601A*
Cooling Capacity, BTUH 42,000 48,000 60,000
Compressor
R.L. Amps
17.9 19.8 26.4
L.R. Amps 112.0 109.0 134.0
High Pressure Switch
Open 610 PSIG 610 PSIG 610 PSIG
Close 420 PSIG 420 PSIG 420 PSIG
Condenser Fan Motor
Horsepower 1/6 1/4 1/4
F.L. Amps 1.10 1.50 1.50
Liquid Line, Inches O.D.* 3/8" 3/8" 3/8"
Suction Line, Inches O.D.* 7/8" 7/8" 7/8"
Refrigerant Charge
151.0 166.0 184.0
Power Supply 208/230-60-1 208/230-60-1 208/230-60-1
Minimum Circuit Ampacity
(1 )
23.
5
26.
3
34.5
Maximum Overcurrent Device
(2)
40 45 60
Electrical Conduit Size
Power Supply (Inches) 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4
Approxim ate Shipping Weight
219 225 240