Goodman Mfg GSX Air Conditioner User Manual


 
26
COOLING PERFORMANCE DATA
GSX130181B*/VSX130181A*
MODEL: GSX130181B* / CA*F1824*6B*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67 715963677159636771
MBh 15.8 16.4 17.9 - 15.4 16.0 17.5 - 15.1 15.6 17.1 - 14.7 15.2 16.7 - 14.0 14.5 15.9 - 12.9 13.4 14.7 -
S/T 0.67 0.56 0.39 - 0.69 0.58 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.77 0.64 0.44 -
Delta T181612 - 191612 - 191612 - 19 16 12 - 191612 - 171511 -
525 KW 1.27 1.30 1.34 - 1.36 1.39 1.43 - 1.44 1.47 1.51 - 1.51 1.54 1.59 - 1.57 1.60 1.65 - 1.62 1.65 1.71 -
AMPS4.64.74.8 - 4.95.05.2 - 5.35.55.6 - 5.7 5.8 6.0 - 6.06.26.4 - 6.46.66.8 -
HI PR 203 218 230 - 228 245 259 - 259 279 294 - 295 317 335 - 332 357 377 - 366 394 416 -
LO PR 103 109 119 - 109 116 126 - 113 120 131 - 119 126 138 - 124 132 144 - 129 137 149 -
MBh 17.1 17.7 19.4 - 16.7 17.3 19.0 - 16.3 16.9 18.5 - 15.9 16.5 18.1 - 15.1 15.7 17.2 - 14.0 14.5 15.9 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.41 - 0.74 0.61 0.43 - 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.79 0.66 0.46 -
Delta T181612 - 181612 - 181612 - 19 16 12 - 181612 - 171511 -
70 600 KW 1.30 1.33 1.37 - 1.39 1.42 1.46 - 1.48 1.51 1.55 - 1.55 1.58 1.63 - 1.61 1.64 1.69 - 1.66 1.70 1.75 -
AMPS4.74.85.0 - 5.15.25.3 - 5.55.65.8 - 5.9 6.0 6.2 - 6.26.46.6 - 6.66.77.0 -
HI PR 209 225 238 - 235 252 267 - 267 287 303 - 304 327 345 - 342 368 389 - 378 407 429 -
LO PR 106 113 123 - 112 119 130 - 116 124 135 - 122 130 142 - 128 136 149 - 133 141 154 -
MBh 17.6 18.3 20.0 - 17.2 17.9 19.6 - 16.8 17.4 19.1 - 16.4 17.0 18.6 - 15.6 16.2 17.7 - 14.4 15.0 16.4 -
S/T 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.45 - 0.80 0.66 0.46 - 0.83 0.69 0.48 - 0.83 0.70 0.48 -
Delta T171511 - 181512 - 181512 - 18 15 12 - 181512 - 161411 -
675 KW 1.31 1.34 1.38 - 1.40 1.43 1.48 - 1.49 1.52 1.56 - 1.56 1.59 1.64 - 1.62 1.65 1.71 - 1.67 1.71 1.76 -
AMPS4.74.85.0 - 5.15.25.4 - 5.55.75.8 - 5.9 6.0 6.2 - 6.36.46.6 - 6.66.87.0 -
HI PR 211 227 240 - 237 255 269 - 270 290 306 - 307 330 349 - 345 372 392 - 382 411 434 -
LO PR 107 114 124 - 113 120 131 - 118 125 137 - 123 131 143 - 129 138 150 - 134 142 155 -
MBh 16.116.517.919.215.716.217.518.815.315.817.118.315.0
15.4
16.7 17.9 14.2 14.6 15.8 17.0 13.2 13.5 14.7 15.7
S/T 0.760.680.510.330.790.700.530.340.810.720.550.350.83
0.74
0.56 0.36 0.86 0.77 0.58 0.38 0.87 0.78 0.59 0.38
Delta T21201611222016112220161122
20
16 11 21 20 16 11 20 18 15 10
525 KW 1.281.311.351.391.371.401.441.491.451.481.531.571.52
1.55
1.60 1.65 1.58 1.62 1.67 1.72 1.63 1.67 1.72 1.77
AMPS 4.6 4.7 4.9 5.0 5.0 5.1 5.2 5.4 5.4 5.5 5.7 5.9 5.7
5.9
6.1 6.36.16.36.56.76.56.66.87.1
HI PR 205 220 233 243 230 247 261 272 261 281 297 310 298
320
338 353 335 361 381 397 370 398 421 439
LO PR 104 111 121 128 110 117 127 136 114 121 132 141 120
127
139 148 126 134 146 155 130 138 151 161
MBh 17.417.919.420.817.017.519.020.316.617.118.519.916.2
16.7
18.1 19.4 15.4 15.8 17.2 18.4 14.3 14.7 15.9 17.1
S/T 0.790.700.530.340.810.730.550.350.840.750.570.360.86
0.77
0.58 0.38 0.90 0.80 0.61 0.39 0.90 0.81 0.61 0.39
Delta T21191611212016112120161121
20
16 11 21 19 16 11 20 18 15 10
75 600 KW 1.311.341.381.421.401.431.481.521.491.521.561.611.56
1.59
1.64 1.69 1.62 1.65 1.71 1.76 1.67 1.71 1.76 1.82
AMPS 4.7 4.8 5.0 5.2 5.1 5.2 5.4 5.6 5.5 5.7 5.8 6.1 5.9
6.0
6.2 6.56.36.46.66.96.66.87.07.3
HI PR 211 227 240 250 237 255 269 281 270 290 306 319 307
330
349 364 345 372 392 409 382 411 434 452
LO PR 107 114 124 132 113 120 131 140 118 125 137 145 124
131
143 153 129 138 150 160 134 142 156 166
MBh 17.918.520.021.517.518.019.521.017.117.619.120.516.7
17.2
18.6 20.0 15.9 16.3 17.7 19.0 14.7 15.1 16.4 17.6
S/T 0.820.740.560.360.850.760.580.370.880.780.590.380.90
0.81
0.61 0.39 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41
Delta T20191510201915112019151121
19
16 11 20 19 15 11 19 17 14 10
675 KW 1.321.351.391.431.421.441.491.531.501.531.571.621.57
1.60
1.65 1.70 1.63 1.67 1.72 1.77 1.69 1.72 1.78 1.83
AMPS 4.8 4.9 5.0 5.2 5.1 5.3 5.4 5.6 5.6 5.7 5.9 6.1 6.0
6.1
6.3 6.56.36.56.76.96.76.97.17.4
HI PR 213 230 242 253 239 258 272 284 272 293 309 323 310
334
352 368 349 375 396 413 385 415 438 457
LO PR 108 115 126 134 114 122 133 141 119 126 138 147 125
133
145 154 131 139 152 162 135 144 157 167
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions AMPS=outdoor unit amps (comp.+fan)
Hi
g
h and low
p
ressures are measured at the li
q
uid and suction service valves. KW=Total s
y
stem
p
ower