Goodman Mfg GSX Air Conditioner User Manual


 
32
COOLING PERFORMANCE DATA
GSX130301B*/VSX130301A*
MODEL: GSX130301B* / CA*F3030*6B*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67715963677159636771
MBh 24.9 25.8 28.3 - 24.4 25.2 27.7 - 23.8 24.6 27.0 - 23.2 24.0 26.3 - 22.0 22.8 25.0 - 20.4 21.2 23.2 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.61 0.43 - 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.80 0.66 0.46 -
Delta T 18 16 12 - 18 16 12 - 18 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
875 KW 1.94 1.98 2.03 - 2.08 2.12 2.18 - 2.20 2.25 2.32 - 2.31 2.36 2.43 - 2.40 2.45 2.53 - 2.48 2.54 2.62 -
AMPS 6.8 7.0 7.2 - 7.4 7.6 7.8 - 8.0 8.2 8.5 - 8.6 8.8 9.1 - 9.1 9.3 9.7 - 9.7 9.9 10.2 -
HI PR 228 245 259 - 256 275 291 - 291 313 331 - 332 357 377 - 373 401 424 - 412 443 468 -
LO PR 102 109 119 - 108 115 125 - 112 119 130 - 118 125 137 - 124 131 143 - 128 136 148 -
MBh 27.0 28.0 30.7 - 26.4 27.4 30.0 - 25.8 26.7 29.3 - 25.1 26.1 28.5 - 23.9 24.7 27.1 - 22.1 22.9 25.1 -
S/T 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.82 0.69 0.48 -
Delta T 18 15 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
70 1000 KW 1.98 2.02 2.08 - 2.13 2.17 2.24 - 2.25 2.30 2.37 - 2.37 2.42 2.49 - 2.46 2.51 2.59 - 2.54 2.60 2.68 -
AMPS 7.0 7.2 7.4 - 7.6 7.8 8.0 - 8.2 8.4 8.7 - 8.8 9.0 9.3 - 9.4 9.6 9.9 - 9.9 10.2 10.5 -
HI PR 235 253 267 - 264 284 300 - 300 323 341 - 342 368 388 - 384 414 437 - 425 457 483 -
LO PR 105 112 122 - 111 118 129 - 116 123 134 - 122 129 141 - 127 135 148 - 132 140 153 -
MBh 27.8 28.8 31.6 - 27.2 28.2 30.9 - 26.5 27.5 30.1 - 25.9 26.8 29.4 - 24.6 25.5 27.9 - 22.8 23.6 25.9 -
S/T 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.86 0.72 0.50 -
Delta T 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 16 14 11 -
1125 KW 2.00 2.04 2.10 - 2.14 2.19 2.25 - 2.27 2.32 2.39 - 2.39 2.44 2.51 - 2.48 2.53 2.62 - 2.56 2.62 2.70 -
AMPS 7.1 7.2 7.5 - 7.7 7.8 8.1 - 8.3 8.5 8.8 - 8.9 9.1 9.4 - 9.5 9.7 10.0 - 10.0 10.3 10.6 -
HI PR 237 256 270 - 266 287 303 - 303 326 344 - 345 371 392 - 388 418 441 - 429 462 488 -
LO PR 106 113 124 - 112 120 131 - 117 124 136 - 123 131 143 - 129 137 149 - 133 142 155 -
MBh 25.4 26.1 28.3 30.3 24.8 25.5 27.6 29.6 24.2 24.9 26.9 28.9 23.6
24.3
26.3 28.2 22.4 23.1 25.0 26.8 20.8 21.4 23.1 24.8
S/T 0.790.700.530.340.820.730.550.360.840.750.570.360.86
0.77
0.58 0.38 0.90 0.80 0.61 0.39 0.90 0.81 0.61 0.39
Delta T21191611212016112120161121
20
16 11 21 19 16 11 20 18 15 10
875 KW 1.95 1.99 2.05 2.11 2.09 2.14 2.20 2.27 2.22 2.26 2.33 2.41 2.33
2.38
2.45 2.53 2.42 2.47 2.55 2.63 2.50 2.56 2.64 2.72
AMPS6.97.17.37.67.47.67.98.28.18.38.68.98.6
8.9
9.2 9.5 9.2 9.4 9.7 10.1 9.7 10.0 10.3 10.7
HI PR 230 248 262 273 259 278 294 306 294 316 334 349 335
360
381 397 377 405 428 447 416 448 473 493
LO PR 103 110 120 128 109 116 127 135 113 121 132 140 119
127
138 147 125 133 145 154 129 137 150 160
MBh 27.5 28.3 30.6 32.9 26.8 27.6 29.9 32.1 26.2 27.0 29.2 31.3 25.6
26.3
28.5 30.6 24.3 25.0 27.1 29.0 22.5 23.2 25.1 26.9
S/T 0.820.730.550.360.850.760.570.370.870.780.590.380.90
0.80
0.61 0.39 0.93 0.83 0.63 0.40 0.94 0.84 0.63 0.41
Delta T21191611211916112119161121
19
16 11 21 19 16 11 19 18 15 10
75 1000 KW 2.002.042.102.162.142.192.252.322.272.322.392.472.39
2.44
2.51 2.59 2.48 2.53 2.62 2.70 2.57 2.62 2.70 2.79
AMPS7.17.27.57.87.77.88.18.48.38.58.89.18.9
9.1
9.4 9.8 9.5 9.7 10.0 10.4 10.0 10.3 10.6 11.0
HI PR 238 256 270 282 267 287 303 316 303 326 344 359 345
372
392 409 388 418 441 460 429 462 488 509
LO PR 106 113 124 132 112 120 131 139 117 124 136 145 123
131
143 152 129 137 149 159 133 142 155 165
MBh 28.3 29.1 31.5 33.9 27.6 28.5 30.8 33.1 27.0 27.8 30.1 32.3 26.3
27.1
29.3 31.5 25.0 25.8 27.9 29.9 23.2 23.9 25.8 27.7
S/T 0.860.770.580.370.890.790.600.390.910.810.620.400.94
0.84
0.64 0.41 0.97 0.87 0.66 0.42 0.98 0.88 0.67 0.43
Delta T20181510201815102018151020
19
15 11 20 18 15 10 19 17 14 10
1125 KW 2.012.052.112.182.162.202.272.342.292.342.412.492.40
2.46
2.53 2.61 2.50 2.56 2.64 2.72 2.59 2.64 2.73 2.82
AMPS7.17.37.67.87.77.98.28.58.48.68.99.29.0
9.2
9.5 9.9 9.6 9.8 10.1 10.5 10.1 10.4 10.7 11.1
HI PR 240 258 273 284 269 290 306 319 306 329 348 363 349
375
396 413 392 422 446 465 433 466 493 514
LO PR 107 114 125 133 114 121 132 140 118 126 137 146 124
132
144 153 130 138 151 161 134 143 156 166
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions AMPS=outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and suction service valves. KW=Total system power