Goodman Mfg GSX Air Conditioner User Manual


 
38
COOLING PERFORMANCE DATA
GSX130481B*/VSX130481A*
MODEL: GSX130481B* / CA*F4860*6B*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67715963677159636771
MBh 40.4 41.9 45.9 - 39.5 40.9 44.8 - 38.5 39.9 43.7 - 37.6 38.9 42.7 - 35.7 37.0 40.5 - 33.1 34.3 37.5 -
S/T 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.67 0.47 - 0.81 0.68 0.47 -
Delta T 19 16 12 - 19 16 12 - 19 16 13 - 19 17 13 - 19 16 12 - 18 15 12 -
1400 KW 3.17 3.23 3.32 - 3.39 3.46 3.56 - 3.59 3.66 3.77 - 3.77 3.84 3.96 - 3.91 4.00 4.12 - 4.04 4.13 4.26 -
AMPS 11.6 11.9 12.3 - 12.6 12.9 13.3 - 13.7 14.0 14.5 - 14.6 15.0 15.5 - 15.5 15.9 16.5 - 16.5 16.9 17.4 -
HI PR 215 231 244 - 241 259 274 - 274 295 311 - 312 336 354 - 351 377 399 - 388 417 440 -
LO PR 104 111 121 - 110 117 128 - 115 122 133 - 120 128 140 - 126 134 146 - 130 139 151 -
MBh 43.8 45.4 49.7 - 42.7 44.3 48.5 - 41.7 43.2 47.4 - 40.7 42.2 46.2 - 38.7 40.1 43.9 - 35.8 37.1 40.7 -
S/T 0.73 0.61 0.43 - 0.76 0.64 0.44 - 0.78 0.65 0.45 - 0.81 0.67 0.47 - 0.84 0.70 0.48 - 0.84 0.70 0.49 -
Delta T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -
70 1600 KW 3.24 3.30 3.40 - 3.47 3.54 3.65 - 3.67 3.75 3.87 - 3.86 3.94 4.06 - 4.01 4.09 4.22 - 4.14 4.23 4.36 -
AMPS 12.0 12.3 12.7 - 12.9 13.2 13.7 - 14.1 14.4 14.9 - 15.0 15.4 15.9 - 16.0 16.4 16.9 - 16.9 17.4 17.9 -
HI PR 221 238 251 - 248 267 282 - 282 304 321 - 321 346 365 - 362 389 411 - 400 430 454 -
LO PR 108 114 125 - 114 121 132 - 118 126 137 - 124 132 144 - 130 138 151 - 134 143 156 -
MBh 45.1 46.7 51.2 - 44.0 45.6 50.0 - 43.0 44.5 48.8 - 41.9 43.5 47.6 - 39.8 41.3 45.2 - 36.9 38.2 41.9 -
S/T 0.77 0.64 0.45 - 0.80 0.67 0.46 - 0.82 0.68 0.47 - 0.85 0.71 0.49 - 0.88 0.73 0.51 - 0.88 0.74 0.51 -
Delta T 18 15 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 15 12 - 17 14 11 -
1800 KW 3.26 3.33 3.42 - 3.50 3.57 3.67 - 3.70 3.78 3.90 - 3.89 3.97 4.09 - 4.04 4.13 4.26 - 4.18 4.26 4.40 -
AMPS 12.1 12.4 12.8 - 13.0 13.4 13.8 - 14.2 14.5 15.0 - 15.2 15.5 16.0 - 16.1 16.5 17.1 - 17.1 17.5 18.1 -
HI PR 223 240 254 - 251 270 285 - 285 307 324 - 325 349 369 - 365 393 415 - 404 434 459 -
LO PR 109 116 126 - 115 122 133 - 119 127 139 - 125 133 146 - 131 140 152 - 136 144 158 -
MBh 41.1 42.3 45.8 49.1 40.1 41.3 44.7 48.0 39.2 40.3 43.7 46.8 38.2
39.3
42.6 45.7 36.3 37.4 40.5 43.4 33.6 34.6 37.5 40.2
S/T 0.81 0.72 0.55 0.35 0.83 0.75 0.56 0.36 0.86 0.77 0.58 0.37 0.88
0.79
0.60 0.38 0.92 0.82 0.62 0.40 0.92 0.83 0.63 0.40
Delta T22201611222017112220171122
20
17 12 22 20 16 11 20 19 15 11
1400 KW 3.19 3.25 3.35 3.45 3.42 3.49 3.59 3.70 3.62 3.69 3.80 3.92 3.79
3.87
3.99 4.12 3.95 4.03 4.15 4.29 4.08 4.16 4.29 4.43
AMPS 11.7 12.0 12.4 12.9 12.7 13.0 13.4 13.9 13.8 14.1 14.6 15.1 14.7
15.1
15.6 16.2 15.7 16.1 16.6 17.2 16.6 17.0 17.6 18.3
HI PR 217 233 246 257 243 262 276 288 277 298 314 328 315
339
358 373 354 381 403 420 391 421 445 464
LO PR 105 112 122 130 111 118 129 138 116 123 134 143 122
129
141 150 127 136 148 158 132 140 153 163
MBh 44.5 45.8 49.6 53.2 43.5 44.8 48.4 52.0 42.4 43.7 47.3 50.8 41.4
42.6
46.1 49.5 39.3 40.5 43.8 47.0 36.4 37.5 40.6 43.6
S/T 0.84 0.75 0.57 0.36 0.87 0.77 0.59 0.38 0.89 0.79 0.60 0.39 0.92
0.82
0.62 0.40 0.95 0.85 0.64 0.41 0.96 0.86 0.65 0.42
Delta T21201611222016112220161122
20
16 11 21 20 16 11 20 18 15 10
75 1600 KW 3.26 3.33 3.42 3.53 3.50 3.57 3.68 3.79 3.70 3.78 3.90 4.02 3.89
3.97
4.09 4.22 4.04 4.13 4.26 4.39 4.18 4.26 4.40 4.54
AMPS 12.1 12.4 12.8 13.2 13.1 13.4 13.8 14.3 14.2 14.5 15.0 15.6 15.2
15.5
16.1 16.7 16.1 16.5 17.1 17.7 17.1 17.5 18.1 18.8
HI PR 223 240 254 265 251 270 285 297 285 307 324 338 325
349
369 385 365 393 415 433 404 434 459 478
LO PR 109 116 126 134 115 122 133 142 119 127 139 148 125
133
146 155 131 140 153 162 136 145 158 168
MBh 45.8 47.2 51.1 54.8 44.8 46.1 49.9 53.6 43.7 45.0 48.7 52.3 42.6
43.9
47.5 51.0 40.5 41.7 45.1 48.5 37.5 38.6 41.8 44.9
S/T 0.88 0.78 0.59 0.38 0.91 0.81 0.61 0.40 0.93 0.83 0.63 0.41 0.96
0.86
0.65 0.42 1.00 0.89 0.67 0.43 1.00 0.90 0.68 0.44
Delta T21191511211916112119161121
19
16 11 21 19 16 11 19 18 15 10
1800 KW 3.29 3.35 3.45 3.55 3.52 3.59 3.70 3.82 3.73 3.81 3.93 4.05 3.92
4.00
4.12 4.26 4.07 4.16 4.29 4.43 4.21 4.30 4.44 4.58
AMPS 12.2 12.5 12.9 13.4 13.2 13.5 13.9 14.5 14.3 14.7 15.1 15.7 15.3
15.7
16.2 16.8 16.3 16.7 17.2 17.9 17.3 17.7 18.3 19.0
HI PR 226 243 256 267 253 272 288 300 288 310 327 341 328
353
373 389 369 397 419 437 408 439 463 483
LO PR 110 117 127 136 116 123 135 143 120 128 140 149 127
135
147 157 133 141 154 164 137 146 159 170
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions AMPS=outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and suction service valves. KW=Total system power