COOLING PERFORMANCE DATA
MODEL: GSX130181B* / CA*F1824*6B*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67 715963677159636771
MBh 16.4 16.7 17.9 19.1 16.0 16.3 17.4 18.6 15.6 15.9 17.0 18.2 15.2 15.6 16.6 17.8 14.5 14.8 15.8 16.9 13.4 13.7 14.6 15.6
S/T 0.83 0.78 0.63 0.47 0.86 0.81 0.66 0.49 0.88 0.83 0.67 0.50 0.91 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.95 0.90 0.73 0.54
Delta T24232016242320162423201624 23 20 162423201622211915
525 KW 1.29 1.32 1.36 1.40 1.38 1.41 1.45 1.50 1.46 1.49 1.54 1.59 1.53 1.57 1.61 1.66 1.59 1.63 1.68 1.73 1.65 1.68 1.73 1.79
AMPS4.64.84.95.15.05.15.35.55.45.65.76.05.8 5.9 6.1 6.46.26.36.56.86.56.76.97.2
HI PR 207 223 235 245 232 250 264 275 264 284 300 313 301 324 342 357 338 364 385 401 374 402 425 443
LO PR 105 112 122 130 111 118 129 137 115 123 134 143 121 129 141 150 127 135 147 157 131 140 152 162
MBh 17.7 18.1 19.4 20.7 17.3 17.7 18.9 20.2 16.9 17.3 18.5 19.7 16.5 16.8
18.0
19.2 15.7 16.0 17.1 18.3 14.5 14.8 15.8 16.9
S/T 0.86 0.81 0.66 0.49 0.89 0.84 0.68 0.51 0.92 0.86 0.70 0.52 0.95 0.89
0.72
0.54 0.98 0.92 0.75 0.56 0.99 0.93 0.76 0.56
Delta T23222016242320162423201624 23
20
16 24 23 20 16 22 21 18 15
80 600 KW 1.32 1.35 1.39 1.43 1.42 1.44 1.49 1.53 1.50 1.53 1.58 1.62 1.57 1.60
1.65
1.71 1.63 1.67 1.72 1.77 1.69 1.72 1.78 1.83
AMPS 4.8 4.9 5.0 5.2 5.1 5.3 5.4 5.6 5.6 5.7 5.9 6.1 6.0 6.1
6.3
6.56.36.56.76.96.76.97.17.4
HI PR 213 230 242 253 239 258 272 284 272 293 309 323 310 334
352
368 349 375 396 413 385 415 438 457
LO PR 108 115 126 134 114 122 133 141 119 126 138 147 125 133
145
154 131 139 152 162 135 144 157 167
MBh 18.3 18.7 19.9 21.3 17.8 18.2 19.5 20.8 17.4 17.8 19.0 20.3 17.0 17.4 18.5 19.8 16.1 16.5 17.6 18.8 14.9 15.3 16.3 17.4
S/T 0.90 0.85 0.69 0.52 0.94 0.88 0.72 0.53 0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.57 1.00 0.97 0.79 0.59 1.00 1.00 0.79 0.59
Delta T22221915232219152322191523 22 19 152222191520211814
675 KW 1.33 1.36 1.40 1.44 1.43 1.45 1.50 1.54 1.51 1.54 1.59 1.64 1.58 1.62 1.67 1.72 1.65 1.68 1.73 1.79 1.70 1.74 1.79 1.85
AMPS4.84.95.15.35.25.35.55.75.65.86.06.26.0 6.2 6.4 6.66.46.56.87.06.86.97.27.4
HI PR 215 232 245 255 242 260 275 287 275 296 313 326 313 337 356 371 352 379 400 418 389 419 442 461
LO PR 109 116 127 135 115 123 134 143 120 128 139 148 126 134 146 156 132 140 153 163 137 145 159 169
MBh 16.6 17.0 17.8 19.0 16.3 16.6 17.4 18.5 15.9 16.2 16.9 18.1 15.5 15.8 16.5 17.6 14.7 15.0 15.7 16.8 13.6 13.9 14.5 15.5
S/T 0.87 0.84 0.76 0.62 0.90 0.87 0.79 0.64 0.93 0.89 0.81 0.65 0.96 0.92 0.83 0.68 0.99 0.96 0.86 0.70 1.00 0.97 0.87 0.71
Delta T25252420262524212625242126 26 24 212625242124232219
525 KW 1.30 1.33 1.37 1.41 1.39 1.42 1.46 1.51 1.47 1.50 1.55 1.60 1.55 1.58 1.63 1.68 1.61 1.64 1.69 1.75 1.66 1.69 1.75 1.80
AMPS4.74.85.05.15.15.25.35.55.55.65.86.05.8 6.0 6.2 6.46.26.46.66.86.66.77.07.2
HI PR 209 225 238 248 235 252 267 278 267 287 303 316 304 327 345 360 342 368 388 405 378 406 429 448
LO PR 106 113 123 131 112 119 130 138 116 124 135 144 122 130 142 151 128 136 149 158 132 141 154 164
MBh 18.0 18.4 19.3 20.5 17.6 18.0 18.8 20.1 17.2 17.5 18.4 19.6 16.8 17.1 17.9 19.1 15.9 16.2 17.0 18.2 14.8 15.0 15.8 16.8
S/T 0.90 0.87 0.79 0.64 0.94 0.90 0.82 0.66 0.96 0.93 0.84 0.68 0.99 0.96 0.86 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.90 0.73
Delta T25252320252524202525242025 25 24 212425232023232219
85 600 KW 1.33 1.36 1.40 1.44 1.43 1.45 1.50 1.54 1.51 1.54 1.59 1.64 1.58 1.62 1.67 1.72 1.65 1.68 1.73 1.79 1.70 1.74 1.79 1.85
AMPS4.84.95.15.35.25.35.55.75.65.86.06.26.0 6.2 6.4 6.66.46.56.87.06.86.97.27.4
HI PR 215 232 245 255 242 260 275 287 275 296 313 326 313 337 356 371 352 379 400 418 389 419 442 461
LO PR 109 116 127 135 115 123 134 143 120 128 139 148 126 134 146 156 132 140 153 163 137 145 159 169
MBh 18.6 18.9 19.8 21.2 18.1 18.5 19.4 20.7 17.7 18.1 18.9 20.2 17.3 17.6 18.4 19.7 16.4 16.7 17.5 18.7 15.2 15.5 16.2 17.3
S/T 0.95 0.91 0.83 0.67 0.98 0.95 0.86 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.73 1.00 1.00 0.94 0.76 1.00 1.00 0.95 0.77
Delta T24242219242423202424232024 24 23 202223221921212118
675 KW 1.34 1.37 1.41 1.45 1.44 1.47 1.51 1.56 1.52 1.55 1.60 1.65 1.60 1.63 1.68 1.73 1.66 1.69 1.75 1.80 1.71 1.75 1.81 1.86
AMPS4.95.05.15.35.25.45.55.75.75.86.06.26.1 6.2 6.4 6.76.46.66.87.16.87.07.27.5
HI PR 218 234 247 258 244 263 278 289 278 299 316 329 316 340 359 375 356 383 404 422 393 423 447 466
LO PR 110 117 128 136 117 124 135 144 121 129 141 150 127 135 148 157 133 142 155 165 138 147 160 171
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions AMPS=outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and suction service valves. KW=Total system power
GSX130181B*/VSX130181A*