SETTINGS
(CONTACT REVERSE) FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM
Fig. 7-3
Limit switch adjustments must be completed
before running contact reverse test.
1. Test contact reverse.
Open door using wall control.
•Lay 2" x 4" board
*
on floor in center of garage
door opening. Fig. 7-3.
•Close door using wall control.
Door should stop and reverse
within 2 seconds of contacting the board.
If door does not reverse properly:
a. Decrease closing force a small amount
by turning the “CLOSE” force adjustment
screw slightly counterclockwise.
b. Test contact reverse again.
c. Repeat steps a. and b. until contact
reverse works properly.
*If you don’t have a 2" x 4" board handy, any object
1-1/2 inches high that can withstand being hit by the
garage door without sustaining damage is fine.
NOTE: If door is
stopping but not reversing,
“CLOSE” limit switch must be moved closer to
door.
SECT 8—BATTERY & VISOR CLIP
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM
Visor Clip
Battery
Battery
Cover
1. Install/replace battery Fig. 8-1.
Using a pen or similar object, gently push in
on tab.
•Cover snaps open. Remove old battery.
•Observe polarity markings (+,-) inside
battery compartment.
Match new battery to polarity markings and
instal new A23, 12 Volt battery.
Replace battery cover.
NOTE: Use only A23, 12 Volt battery.
2. Attach visor clip Fig. 6-1.
Slide clip in slot on back of remote control.
Snap in place.
Model
Number
Fig. 8-1