Stovax GAZCO Linea Balanced Flue Convector Fire Indoor Fireplace User Manual


 
8
INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATION
COVERING THE FOLLOWING MODELS
8651 P8651
Efficiency Class I
Flue Outlet Size 100 Ø / 152mm Ø
Gas Inlet Connection Size 8mm Ø
Wall Thickness - Minimum = 100mm (4") Maximum = 500mm
Linea Replacement Batteries - 3 x 'C' Cells
Handset Replacement Batteries - 3 x 'AAA' Cells
Model
Gas Gas Working
Aeration Injector
Gas Rate Input kW (Gross) Nox
Country
CAT. Type Pressure m
3/
h High Low
Class
Linea NG I
2H
Natural (G20) 20mbar 2 x 8mm 1.7 0.50 5.25 3.5 4 GB, IE
Linea LPG I
3P
Propane (G31) 37mbar 1.2 0.20 5.25 3.5 4 GB, IE
PACKING CHECKLIST
Qty Description
1 Linea assembly including fixing bracket
1 Flue Pipe
1 Terminal Guard
1 Remote Hand Set
1 Terminal Guard Fixing Kit Containing:
4 Wood Screws 1
1
/
4
4 Red Rawlplugs
1 Linea Fixing Kit Containing:
4 Wood Screws 2
1
/
2
4 Brown Rawlplugs
1 Aluminium Tape
1 Sealing Ring
3 ‘C’ Cell Batteries
3 ‘AAA’ Batteries
1 Instruction Manual
1 x 7.5mm
2 x 10mm
AR1330
AR1331