Stovax GAZCO Linea Balanced Flue Convector Fire Indoor Fireplace User Manual


 
19
7.2 Disconnect the thermocouple from the gas valve. See
diagram 8 arrow C.
7.3 Undo the thermocouple nut in the back of the pilot burner
by half a turn. This will release the thermocouple.
7.4 Disconnect the two leads noting the orientation. The lead
with the red tape on is connected to the thermocouple
spade nearest the gas valve. See diagram 9.
WHEN REPLACING WITH A NEW THERMOCOUPLE
TAKE EXTREME CARE TO BEND THE NEW COMPONENT
TO THE EXACT SHAPE AND TO KEEP THE
CONNECTORS IN THE SAME ORIENTATION.
7.5 When replacing the thermocouple into the pilot burner
ensure the component is pushed fully into the hole. There
is a stop on the thermocouple to set the height.
7.6 Lock the retaining nut just enough to grip the
thermocouple.
7.7 Replace the lower panel.
8.1 Remove the lower panel and pull the ignition lead off the
electrode.
8.2 Locate the ignition lead in the control box situated on the
left-hand side of the appliance and disconnect it. See
diagram 10
8.3 Release the wires from the central white clip and carefully
cut the cable ties. This will release the ignition lead. See
diagram 11.
8.4 Replace with a new lead, replace with new cable ties and
fit the wires back into the clip.
8.5 Fit the cover and ensure no wires are trapped.
9.1 Turn the gas off at the isolation device.
9.2 Remove the lower cover. See diagram 6
8. IGNITION LEAD
SERVICING INSTRUCTIONS
REPLACING PARTS
8
AR1344
10
AR1346
11
AR1344
9
AR1346
9. MAGNETIC SAFETY VALVE
C
4.5v
4.5v