4.7 Reassemble in reverse order and replace the pilot gasket
with a new one.
4.8 Check for gas leaks.
5.1 To gain access to the pilot pipe, it is easier if the
thermocouple is removed first. To do this follow section 7.
5.2 Undo the pilot pipe from the top of the gas valve and from
under side of the pilot burner. See diagram 5 arrow B.
5.3 Remove the pipe and the injector will drop out from the
burner. take care not to lose or damage the injector.
5.4 To replace the injector reverse the above procedure.
5.5 Check for gas leaks.
6.1 Remove the lower panel. See diagram 6.
SERVICING INSTRUCTIONS
REPLACING PARTS
6.2 Pull the ignition lead off the electrode and undo the
retaining nut. See diagram 7.
6.3 Replace with a new electrode. Do not over tighten the nut
as this could break the new component.
6.4 Replace the ignition lead and the lower cover.
7.1 Remove the lower panel. See diagram 6.
6. ELECTRODE
7. THERMOCOUPLE
4 6
AR1341
7
AR1349
5
AR1343
5. PILOT INJECTOR
B
x
X = LPG 10
NG 15