Stovax 8545LUC, P8545LUC Indoor Fireplace User Manual


 
8
INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATION
COVERING THE FOLLOWING MODELS:
ASHDON - 8546LUC - P8546LUC / 8544LUC - P8544LUC
CLARENDON - 8545LUC - P8545LUC / 8547LUC - P8547LUC
Model Gas Gas Working Aeration Injector Gas Rate Input kW (Gross) Country
CAT. Type Pressure m
3
/h High Low
8545LUC-8547LUC I
2H
Natural 20 mbar Ø 1 x 14.5 375 0.600 6.4 3.6 GB, IE
8546LUC-8544LUC (G20)
P8545LUC-P8547LUC I
3P
Propane 37 mbar Ø 2 x 12 165 0.221 6.15 3.6 GB, IE
P8546LUC-P8547LUC (G31)
Rear Exit Flue Wall Thickness:
Min Max
200mm 550mm
Efficiency Class I
Flue Outlet Size 100 Ø / 152mm
Gas Inlet Connection Size 8mm Ø
RESTRICTOR REQUIREMENT
Vertical & Horizontal Flue Specification
Vertical Flue Height from Top of Appliance Horizontal Length Restrictor Size
500mm up to 1490mm 250mm up to 1000mm No Restrictor
1500mm up to 3000mm 250mm up to 5000mm 75mm Ø
TOP EXIT - VERTICAL ONLY INCLUDING OFFSET
Vertical Flue Height from Top of Appliance Restrictor Size
3000mm up to 4990mm 52mm Ø
5000mm up to 1000mm 47mm Ø
Packing Checklist
Qty Description
1 Stove
1 Flue Blanking plate
1 Coal Retainer
1 Log set (5 logs)*
1 Ash Panel* (2 Sections)
1 Fixing Kit Containing
1 Instruction Manual
1 Wood Screw
1 Rawplug
1 Box spanner
*Packed in appliance
A B C D E F
ins mm ins mm ins mm ins mm ins mm ins mm
35
3
/
4
654 25
3
/
4
652 17
3
/
4
440 20
1
/
2
520 6
1
/
4
158 3 75
1
AR1618