GarrettCom 6K16 Door User Manual


 
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)
2
www GarrettCom com
..
Fiber Single-mode connector types:
Fiber Port, SC-type: Fiber optic single-mode, 100BASE-FX
Fiber Port, LC-type Fiber SFF single-mode, 100BASE-FX
Fiber Port, 1000BASE-FX, GBIC modules
LEDs: Per Port (one set at the port, one set on rear top) 6K16V only
Per Port (one set at the port) 6K16
LK: Steady ON when media link is operational
ACT: ON with receiver port activity
FDX/HDX: ON = Full-Duplex Mode
OFF = Half-Duplex Mode
100/10: ON = 100Mbps speed
OFF = 10 Mbps
Operating Environment
Ambient Temperature:
-40 to 140 F (-40 to 60C) for UL60950 and Component Parts rating
-60 to 205 F (-50 to 95C) for IEC 60068 Type Test short term rating
Storage Temperature: -60to 210F (-50to 100C)
Ambient Relative Humidity: 5% to 95% (non-condensing)
Altitude: -200 to 13,000 ft. (-60 to 4000m)
Conformal Coating (humidity protection) option: Request quote
Alarm Relay Contacts
One NC indicating internal power, one NC software controllable
Packaging
Enclosure: Rugged High strength sheet metal.
Dimensions: 9.5 in. H x 8.75 in. W x 1.75 in. D
24.1 cm H x 22.2 cm W x 4.4 cm D
Cooling method: Convection, designed for vertical mounting, no fans (6K16V)
Cooling method: fan cooling, three rear fans (6K16)
Weight: 4.21 lbs. (1.9 kg)
Management Console connector
DB-9 for RS-232 “null-modem” cable (sometimes called an X-modem cable)
Power Supply (Internal)
AC Power Connector: IEC-type, male recessed at rear of chassis,
Input Voltage: 100 to 240 VAC (auto-ranging)
Input Frequency: 47 to 63 Hz (auto-ranging)
Power Consumption:
50 watts typical (for a fully loaded fiber model)
30 watts typical (for a fully-loaded copper only model)
DC Power Supply (Options)
-48VDC Power Input Voltage : -36 to -70 VDC
24VDC Power Input Voltage : 18 to 36VDC
125VDC Power Input Voltage : 88 to 300VDC
Std. Terminal Block : “ -, GND, + ”
Power Consumption: same as for AC models, see above