Connect the cable to the indoor unit
1. Indoor/Outdoor connection cable
should be H07RN-F type.
2. Remove the screw, then remove
the window cover.
3. Connect cables according to their
marks to terminals.
4. Wrap those cables not connected
with terminals with insulation
tapes, so that they will not touch
any electrical components.
Cooling only type.
Code wire
lOmm
Cell type
"Conector A"
Terminal block of indoor unit
To outdoor unit
F--- \
!9;
'-../
Cooling & heating
"Cable A" or "Cable B"
Code wire Code wire
4--140mml J--140m l
10mm 10mm
Cooling & heating
"Conector A" or "Conector B"
TerminaI block of indoor unit
To outdoor unit To outdoor unit
Connect the cable to the outdoor unit
1. Remove the electric parts cover from
the outdoor unit.
2. Connect the connective cables to the
terminals as identified with their
respective matched numbers on the
terminal block of indoor and outdoor
units.
3. To prevent the ingress of water, from a
loop of the connective cable as
illustrated in the installation diagram of
indoor and outdoor units.
4. Insulate unused cords (conductors) with
PVC-tape.Process them so they do not
touch any electrical or metal parts.
Cooling only type.
Code wire
10mm
< 12000 Btu/h (Cooling)
Wire connector of outdoor unit
_>12000 Btu/h (Cooling)
"Conector C" o "Conector D"
Wire connector of outdoor unit
I®1 I®1 - _g
Wire-holding board
board
over
rew
Cooling & heating
"Cable C" or "Cable D"
Code wire Code wire
10mm 10mm
< 12000 Btu/h (Cooling/Heating)
Wire connector of outdoor unit
>_12000 Btu/h (Cooling/Heating)
"Conector E" o "Conector F"
Wire connector of outdoor unit
board board