Installation (for qualified installers only) 7
Travis Industries 4050114 100-01149
Installation Warnings:
! Failure to follow all of the requirements may result in property damage, bodily injury, or
even death.
! This heater must be installed by a qualified installer who has gone through a training
program for the installation of direct vent gas appliances.
! This appliance must be installed in accordance with all local codes, if any; if not, in
U.S.A. follow ANSI Z223.1 and NFPA 54(88).
! In Manufactured or Mobile Homes must conform with: In USA, Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280. This appliance may be
installed in Manufactured Housing only after the home is site located.
! The 44 DV XXL is designed to operate on natural gas or propane (LP).
! All exhaust gases must be vented outside the structure of the living-area. Combustion
air is drawn from outside the living-area structure.
! Notify your insurance company before hooking up this fireplace.
! The requirements listed below are divided into sections. All requirements must be met
simultaneously. The order of installation is not rigid – the qualified installer should
follow the procedure best suited for the installation.
Packing List
• Propane Conversion Kit
• Log Set (Log Set, Coals, & Glowing Embers)
• Flex Tube with Pipe Adapter
• Glass Latch Key (to un-latch glass frame)
• Arch Covers (for arched face)
• Firestop (manufactured for the 44 DV XXL)
• (2) Fireback Clips (for ceramic firebacks only)
Additional Items Required
• Faceplate - Includes attachment screws
• Direct Vent (Simpson Dura-Vent Ph. # 800 835-4429)
• Gas Line Equipment (shutoff valve, pipe, etc.)
• Electrical Equipment (min. 18 gauge, grounded line)