FireplaceXtrordinair 44 DV XXL EF Indoor Fireplace User Manual


 
Installation (for qualified installers only) 17
Travis Industries 4050114 100-01149
Vertical Terminations with 0, 2, or 4 45° Offsets
Offset Length Hor. Offset Vert. Rise
None 5" 1'
1' Section 1' 1' 7"
2' Section 1' 9" 2' 4"
3' Section 2' 5" 3'
4' Section 3' 2" 3' 8"
Offset
Length
Horizontal
Offset
Vertical
Rise
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor position.
5 feet
10 feet
(min.)
15 feet
20 feet
25 feet
30 feet
0 feet
35 feet
0 feet
5 feet
6' (max)
5 feet
0 feet
0 feet
5 feet
6' (max)
10 feet
(min.)
15 feet
20 feet
25 feet
30 feet
35 feet
Four 45° Offsets
5 feet
10 feet
15 feet
20 feet
25 feet
30 feet
0 feet
40' (max)
0 feet
5 feet
5 feet
0 feet
0 feet
Restrictor
Position # 5
Restrictor
Position # 6
10 feet
15 feet
20 feet
30 feet
Zero or Two 45° Offsets
5 feet
12'
(max)
NOTE:
Restrictor positions are
based upon lab tests. The
ideal restrictor position may
vary slightly, especially when
the termination is near the
demarkation line.
25 feet
10 feet
12'
(max)
10 feet
Restrictor
Position # 5
Restrictor
Position # 6
35 feet 35 feet
40' (max) 40' (max) 40' (max)