FireplaceXtrordinair 44 DV XXL EF Indoor Fireplace User Manual


 
Installation (for qualified installers only) 11
Travis Industries 4050114 100-01149
Corner Installations
A typical 45° installation uses the minimum framing dimensions shown in the illustration below (NOTE: all
clearances still apply).
Approx. 16"
23-1/8"
1" Standoffs
19-5/8"
19-1/2"
Min. 1" Clearance
60-3/8"
Raised Fireplaces
The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace
(approximately 300 Lbs.) and vent.
The fireplace may not be raised so as to place the ceiling within 75" of the base of the fireplace.
The fireplace may not be raised so as to reduce the fireplace enclosure to less than 75.
Raised fireplace
Raised fireplace with
raised hearth.
Raised
Platform
Raised Hearth
Hearth
Raised
Platform
6-1/4"
6-1/4"