FireplaceXtrordinair 44 DV XXL EF Indoor Fireplace User Manual


 
10 Installation (for qualified installers only)
Travis Industries 4050114 100-01149
Clearances
When installed, walls in front of the fireplace must be a minimum 3-1/2" to the side of the faceplate.
Due to the high temperature, the heater should be located out of traffic and away from furniture and draperies.
Fireplace must be placed so the vents below and above the glass do not become blocked
Vertical Standoff
The vertical standoff above the fireplace must be erected prior to installation. See the illustration below for
instructions.
The vertical standoff is
shipped swiveled down.
Rotate the standoff
upwards into place.
1/4" Nutdriver
Secure the standoff
with the six screws.
These lifting
handles may be
removed once
the fireplace is
in place.
7/16" Wrench
Nail or screw the
fireplace to the
floor through the
holes on these
brackets.