Enviro C-10135 Stove User Manual


 
Installation
THROUGH WALL WITH VERTICAL RISE INSTALLATIONS:
Wall framing
Wall thimble
Termination cap
Vent pipe
Horizontal frame
for thimble
 
Wall framing
Wall thimble
Termination cap
Vertical section
of vent pipe
Horizontal frame
for thimble
Clean out tee
90 deg elbow
 
Concrete Wall
Wall framing
Wall thimble
Termination cap
Vertical section
of vent pipe
Horizontal frame
for thimble
Clean out tee
90 deg elbow
 
Wall strap
STRAIGHT THROUGH WALL INSTALLATIONS:
The termination must be 12 inches (30 cm) from the
outside wall and 12 inches (30 cm) above the ground.
A 45° elbow with a rodent screen may be used in place
of the termination cap (or stainless steel termination
hood).
Installation to use if there is a concrete or retaining wall
in line with exhaust vent on pellet stove.
The termination must be 12 inches (30 cm) from the
outside wall and 12 inches (30 cm) above the ground.
This is the recommended installation set up.
A 45° elbow with a rodent screen may be used in place of the termination cap (or stainless steel
termination hood).
18