Enviro C-10135 Stove User Manual


 
17
The MERIDIAN can be vented through the wall using two different methods. Only use vent of (L or PL) type with
an inside diameter of 3 or 4 inches (7.6 or 10.1 cm)
VENT INSTALLATION: INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces, or a floor,
or ceiling. Where passage through a wall, or partition of combustible construction is desired, the installation shall
conform to CAN/CSA-B365, Installation Code for Solid-Fuel-Burning Appliances and Equipment.
STRAIGHT THROUGH THE WALL.
1. Choose a location for your stove that meets the requirements stated in this manual and allows installation
with the least amount of interference to house framing, plumbing, wiring, etc.
2. Place the appliance 15” (37.5 cm) away from the wall. If the stove is to be set on a hearth pad, set the unit
on it.
3. Locate the center of the exhaust pipe on the stove. Extend that line to the wall. Once you have located the
center point on the wall, use a hole saw to cut a 10” (254 mm) diameter hole for a 3” (76 mm) vent pipe or
an 11” (279 mm) hole for a 4” (101 mm) vent pipe.
4. Install the wall thimble as per the instructions written on the thimble. Maintain an effective vapour barrier
in accordance with local building codes.
5. Install a length of 3” (76 mm) or 4” (101 mm) vent pipe into the wall thimble. The pipe should install easily
into the thimble.
6. Install the fresh air intake.
7. Connect the exhaust vent pipe to the exhaust pipe on the stove. Seal all connections with high temperature
silicone
8. Push the stove straight back, leaving a minimum of 3” (7.6 cm) clearance from the back of the stove to the
wall. Seal the vent pipe to the thimble with high temperature silicone.
9. The pipe must extend at least 12” (30 cm) away from the building. If necessary, bring another length of pipe
(PL type) to the outside of the home to connect to the first section. Do not forget to place high temperature
silicone around the pipe that passes through the thimble.
10. Install a vertical pipe, or if all requirements for direct venting are met, install vent termination. The stainless
steel cap termination manufactured by the vent manufacturer is recommended. However, when the vent
terminates several feet above ground level and there are no trees, plants, etc. within several feet, a 45°
elbow with rodent screen can be used as a termination. The elbow must be turned down to prevent rain
from entering.
NOTE:
• Some horizontal through wall installations
may require a “T” and a 3 to 5 foot (91-
152cm) of vertical pipe outside the building
to help natural draft in the unit.
• This may be required if a proper burn
cannot be maintained, after the stove has
been tested and the airflow set.
• This is due to the backpressure in the
exhaust caused by airflow around the
structure.
• All sections of pipe must have three (3)
screws evenly spaced and all horizontal
vent sections must have a bead of high
temperature silicone installed on the male
end of the pipe before installation to create
a gastight seal.
Installation
THROUGH WALL INSTALLATION:
Exhaust Tube
3" (75mm) or 4" (100mm)
"PL" or "L" vent
Wall Thimble
45 deg Elbow
w/screen or
Termination Cap
Fresh Air Intake
High Temperature RTV
Silicone Required