Enviro C-10135 Stove User Manual


 
Fuel: This pellet stove is designed and approved to only burn wood pellet fuel with up to 3% ash content. Dirty
fuel will adversely affect the operation and performance of the unit and may void the warranty. Check with your
dealer for fuel recommendations.
THE USE OF CORDWOOD IS PROHIBITED BY LAW.
Soot: Operation of the stove with insufficient combustion air will result in the formation of soot which will collect on
the glass, the heat exchanger, the exhaust vent system, and may stain the outside of the house. This is a dangerous
situation and is inefficient. Frequently check your stove and adjust the slider/damper as needed to ensure proper
combustion. See: “Operation - Slider/Damper Setting”
Cleaning: There will be some build up of fly ash and small amounts of creosote in the exhaust. This will vary due
to the ash content of the fuel used and the operation of the stove. It is advisable to inspect and clean the exhaust
vent annually or every two tons of pellets.
Ashes: Disposed ashes should be placed in a metal container with a tight fitting lid. The closed container of
ashes should be on a non-combustible floor on the ground, well away from all combustible materials pending final
disposal. If the ashes are disposed of by burial in soil or otherwise locally dispensed, they should be retained in the
closed container until all cinders have been thoroughly cooled.
Electrical: THE USE OF A SURGE PROTECTED POWER BAR IS RECOMMENDED.
The maximum power requirement is 550 watts (4.6 amp). The stove has a grounded electrical cord and should be
connected to a standard 115 volt, 60-Hz grounded electrical outlet. Make sure the electrical cord is not trapped
under the appliance and that it is clear of any hot surfaces or sharp edges. When installing the stove in a mobile
home, it must be electrically grounded to the steel chassis of the home and bolted to the floor in accordance with
applicable local, state or federal codes.
TO PREVENT THE POSSIBILITY OF A FIRE, THIS APPLIANCE MUST BE PROPERLY
INSTALLED BY FOLLOWING THE INSTALLATION INSTRUCTIONS. PLEASE READ
THIS ENTIRE OWNER’S MANUAL BEFORE INSTALLING OR OPERATING YOUR
ENVIRO PELLET STOVE. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT
IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH. CONTACT YOUR LOCAL
BUILDING OR FIRE OFFICIALS TO OBTAIN A PERMIT AND ANY INFORMATION ON ANY
INSTALLATION RESTRICTIONS AND INSPECTION REQUIREMENTS FOR YOUR AREA.
An ENVIRO dealer will be happy to assist you.
THE STOVE’S EXHAUST SYSTEM WORKS WITH NEGATIVE COMBUSTION CHAMBER
PRESSURE AND A SLIGHTLY POSITIVE CHIMNEY PRESSURE.
IT IS VERY IMPORTANT TO ENSURE THAT THE EXHAUST
SYSTEM BE SEALED AND IS AIRTIGHT.
4
IMPORTANT SAFETY DATA:
SAFETY WARNINGS AND RECOMMENDATIONS:
Introduction
RATING LABEL LOCATION:
Freestanding:
The rating label is located on the inside of the hopper lid.
Insert:
The rating label is located on the hopper cover.