Outside fresh air is mandatory when installing this unit in airtight homes and mobile homes. When
connecting to an outside fresh air source, do not use plastic, combustible pipe. Only 2” ID (inside diameter) steel,
aluminum or copper pipe should be used. It is recommended, when you are installing a fresh air system, to keep
the number of bends in the pipe to a minimum.
EXHAUST AND FRESH AIR INTAKE LOCATIONS
EXHAUST Freestanding Insert
Base to center of flue 18 ” (47.3 cm) 9
1
/16” (22.9 cm)
Side to center of flue 6
11
/16” (17.0 cm) 6 ” (15.6 cm)
FRESH AIR INTAKE.
Base to center of intake 13
1
/16” (33.2 cm) 3
7
/16” (8.7 cm)
Side to center of intake 11
7
/16” (29.1 cm) 10 ” (27.7 cm)
INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENTING MANUFACTURER
Installation
OUTSIDE FRESH AIR CONNECTION:
● Secure the heater to the floor using the holes in
the pedestal of the appliance.
Ensure the unit is electrically grounded to the
chassis of your home (permanently).
WARNING: DO NOT INSTALL IN A ROOM
PEOPLE SLEEP IN.
CAUTION: THE STRUCTURAL INTEGRITY
OF THE MANUFACTURED HOME FLOOR,
WALL AND CEILING/ROOF MUST BE
MAINTAINED
Outside fresh air is mandatory. Secure outside
air connections directly to fresh air intake pipe and
secure with three (3) screws evenly spaced.
MOBILE HOME INSTALLATION:



ENVIRO MERIDIAN
1/4” LAG BOLTS
SECURELYFASTENED
GROUND WIRE DIRECTLY
TO METAL CHASSIS
HEARTH PAD
FLOORING
STEEL FRAME