Enviro C-10135 Stove User Manual


 
1. Check clearances to combustibles.
2. Do not obtain combustion air from an attic, garage, or any unventilated space. Combustion air may be obtained
from a ventilated crawlspace.
3. Do not install the stove in a bedroom.
4. You can vent the stove through an exterior wall behind the unit or connect it to an existing masonry or metal
chimney (must be lined if the chimney is over 6” (15.2cm) in diameter, or over 28 sq. inches (180.6 cm²) cross
sectional area). An interior vent can be used with approved pipe passing through the ceiling and roof.
5. Locate the stove in a large and open room that is centrally located in the house. This will optimize heat
circulation.
6. The power cord is 8 feet (2.43 m) long and may require a grounded extension cord to reach the nearest electrical
outlet.
12
Installation
DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE:
To remove your new stove from its pallet, remove the two screws securing the bottom to the pallet. On the
freestanding model one can be easily seen from behind but to access the second the ashpan must be removed. On
the insert model there is one screw on either side of the bottom.
REMOVING YOUR PELLET APPLIANCE FROM THE PALLET: