Installation
INSERT CLEARANCES TO COMBUSTIBLES (INSTALLED IN MASONRY FIREPLACE):
The fireplace insert model includes a surround faceplate and a pedestal. When installing this unit, ensure that the
pedestal is removed from the inside of the hopper and installed on the bottom of the unit.
SIDE WALL 8 inches (20.3 cm) from the body of the heater
FACING ON MASONRY FIREPLACE 8 inches (20.3 cm) from the body of the heater
MANTLE 8 inches (20.3 cm) from the body of the heater
FREESTANDING CLEARANCES TO COMBUSTIBLES AND MINIMUM ALCOVE SIZE:
Maintain these clearances to combustibles. This unit may be installed in an Alcove.
SIDE WALL TO UNIT 6 inches (20.4 cm) MIN. ALCOVE WIDTH 36 inches ( 91.4 cm)
BACK WALL TO UNIT 3 inches ( 7.6 cm) MIN. ALCOVE HEIGHT 48 inches (121.9 cm)
ADJACENT WALL 2 inches ( 5.0 cm) MIN. ALCOVE DEPTH 30 inches ( 76.2 cm)






INSERT DIMENSIONS:
WIDTH: 23  inches (60.4 cm)
HEIGHT: 22  inches (64.6 cm)
DEPTH: 23  inches (60.5 cm)