Enviro 50-927 Indoor Fireplace User Manual


 
Figure 48. Install Fan Control Box. Figure 49. Plug In Fan Kit.
30
Secondary Installation
Installation of Kit:
1. Ensure the appliance is turned off and cool.
2. Remove the bottom louvers.
3. Place fan in lower area of unit behind the controls (see Figure 46).
4. Hook the two (2) slots on the fan box over the two (2) grommets on the back wall, refer to Figure
47.
5. Using two (2) T-20 screws, attach the fan control box to the ignitor control panel, refer to Figure 48.
Before tightening the screws ensure that the thermal switch on top of the box rmly contacts the rebox
bottom.
6. Plug the fan into the hard wired electrical box/outlet (refer to Figure 49) that was installed in the
INITIAL INSTALLATION - INSTALLATION OF ELECTRICAL OUTLET FOR OPTIONAL FAN KIt“.
Figure 47. Hook Fan Tabs Over Grommets at Unit Back.
Grommets
Slots to go
over grommets