Enviro 50-927 Indoor Fireplace User Manual


 
Secondary Installation
QUALIFIED INSTALLERS ONLY
OPTIONAL FAN KIT INSTALLATION:
The optional fan is thermostatically controlled and it will not operate if the appliance is cold. A few
minutes after the appliance is lit and the variable speed control is set at a desired setting, the fan will
automatically turn on. The fan will automatically turn off a few minutes after the appliance is shut off.
Kit Contents:
This kit includes a fan assembly (a fan within a box
housing connected by a wire to the fan control box
then ends at a three prong plug) and two (2) T-20
torx screws.
Please ensure that your fan kit has not been
damaged. If so, contact your dealer, distributor, or
courier company before starting this installation.
Figure 45. Wiring Diagram For Fan Control.
The replace must be electrically
connected and grounded in accordance
with local codes or, in the absence of
local codes, with the current CSA C22.1
Canadian Electrical Code Part 1, Safety
Standards For Electrical Installations, or
The National Electrical Code ANSI / NFPA
70 in the US.
WARNING: The electrical grounding
instructions must be followed. The
fan kit is equipped with a three-prong
(grounding) plug for your protection
against shock hazard, and should be
plugged directly into a properly grounded
three-prong outlet. DO NOT cut or remove
the grounding prong from this plug.
CAUTION: When servicing controls, label
all wires prior to disconnection. Wiring
errors can cause improper and dangerous
operation. Verify proper operation after
servicing.
Fan Control
Black
Black
Black
Black
Black
Black
White
White
White
Green/Yellow
Green
Green
White
120
o
F (49
o
C)
Temperature Sensor
Fan
Electrical Cord
Electrical
Power Cord
29