When planning an installation, it is necessary to select the
proper length of vent pipe for the particular requirements. The
conguration of the venting pipes depends on the locations
of walls, ceilings and studs. However, the pipes cannot be
of arbitrary length and arrangement. Because the length of
the vertical and horizontal sections dramatically affects the
burning efciency of the replace, certain guidelines have
been set in the Vent Congurations section.
Figure 21. Vent Framing Through Wall/Ceiling.Figure 20. Vent Pipe Clearances.
Figure 22. Wall/Ceiling Thimble provided.
17
Initial Installation
QUALIFIED INSTALLERS ONLY
Venting terminals cannot be recessed into a wall or
siding.
A two (2) piece wall/ceiling thimble is included with
the stove (see Figure 22).
2" (51mm)
3" (76mm)
41
3
/4"
(1048mm)
Framing
Joists/Studs
10”
10”